A Field Evaluation of Construction Workers’ Activity, Hydration Status, and Heat Strain in the Extreme Summer Heat of Saudi Arabia

Author:

Al-Bouwarthan Mohammed12ORCID,Quinn Margaret M1ORCID,Kriebel David1,Wegman David H13

Affiliation:

1. Department of Public Health, College of Health Sciences, University of Massachusetts Lowell, Lowell, MA, USA

2. Department of Environmental Health, College of Public Health, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia

3. La Isla Network, Ada, MI, USA

Abstract

Abstract Objectives Assess the impact of summer heat exposure (June–September) on residential construction workers in Al-Ahsa, Saudi Arabia by evaluating (i) heart rate (HR) responses, hydration status, and physical workload among workers in indoor and outdoor construction settings, (ii) factors related to physiological responses to work in hot conditions, and (iii) how well wet-bulb globe temperature-based occupational exposure limits (WBGTOELs) predict measures of heat strain. Methods Twenty-three construction workers (plasterers, tilers, and laborers) contributed 260 person-days of monitoring. Workload energy expenditure, HR, fluid intake, and pre- and postshift urine specific gravity (USG) were measured. Indoor and outdoor heat exposures (WBGT) were measured continuously and a WBGTOEL was calculated. The effects of heat exposure and workload on heart rate reserve (HRR), a measure of cardiovascular strain, were examined with linear mixed models. A metric called ‘heat stress exceedance’ (HSE) was constructed to summarize whether the environmental heat exposure (WBGT) exceeded the heat stress exposure limit (WBGTOEL). The sensitivity and specificity of the HSE as a predictor of cardiovascular strain (HRR ≥30%) were determined. Results The WBGTOEL was exceeded frequently, on 63 person-days indoors (44%) and 91(78%) outdoors. High-risk HRR occurred on 26 and 36 person-days indoors and outdoors, respectively. The HSE metric showed higher sensitivity for HRR ≥30% outdoors (89%) than indoors (58%) and greater specificity indoors (59%) than outdoors (27%). Workload intensity was generally moderate, with light intensity work more common outdoors. The ability to self-pace work was associated with a lower frequency of HRR ≥30%. USG concentrations indicated that workers began and ended their shifts dehydrated (USG ≥1.020). Conclusions Construction work where WBGTOEL is commonly exceeded poses health risks. The ability of workers to self-pace may help reduce risks.

Funder

Saudi Ministry of Education and Imam Abdulrahman Bin Faisal University

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health

Reference113 articles.

1. Physiological demands during construction work;Abdelhamid;J Constr Eng Manage,2002

2. Assessment of heat stress exposure among construction workers in the hot desert climate of Saudi Arabia;Al-Bouwarthan;Ann Work Expo Health,2019

3. Implications for workability and survivability in populations exposed to extreme heat under climate change: a modelling study;Andrews;Lancet Planet Health,2018

4. Hydration status of expatriate manual workers during summer in the middle East;Bates;Ann Occup Hyg,2010

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3