Abstract

Abstract Objectives The high demand of filtering facepiece respirators (FFRs) worldwide during the period of the COVID-19 pandemic has led to a critical situation for decision-makers regarding their supply. After authorizing the use of FFRs certified by other regions of the world, decision-makers in many countries have published alerts, particularly concerning the ‘KN95’ type. Methods This paper investigated the filtration performance of different FFRs using an experimental setup already employed during several studies on FFRs filtration performance. Its high-resolution measuring devices permit to determine filtration performance according to the normative criteria: the pressure drop and the filtration efficiency. Eight different FFRs have been used: four NIOSH-approved FFRs and four not NIOSH-approved with a ‘KN95’ shape available during the beginning of the COVID-19 pandemic. Results The data show a high disparity between different FFRs purchased by healthcare establishments, and between those that are NIOSH-approved and those that are not NIOSH-approved. The results confirm that the NIOSH certification offers good protection according to the normative criteria. The ‘KN95’ types present pressure drops which correspond to the normative value, however their efficiencies are lower than the efficiencies of FFRs certified by NIOSH and lower than 95% at the most penetrate particle size. Conclusions FFRs marking is not sufficient to conclude on the FFRs’ efficiency. Visual inspection can not determine which samples are counterfeit or have manufacturing defects.

Funder

Institut de recherché Robert Sauvé en Santé et en sécurité du Travail

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health

Reference22 articles.

1. Evaluation of N95 filtering facepiece respirator efficiency with cyclic and constant flows;Bahloul;J Occup Environ Hyg,2014

2. Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles;Balazy;Ann Occup Hyg,2006

3. Filter efficiency as a function of nanoparticle velocity and shape;Boskovic;J Aerosol Sci,2008

4. Filtration of nanoparticles applied in general ventilation;Brochot;Sci Technol Built Environ,2019

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3