Increase of PEth after Single Consumption of Alcohol and Evaluation of a Volumetric DBS Filter Paper Device

Author:

Stöth Frederike12ORCID,Koch Kevin3ORCID,Bantle Matthias1ORCID,Pütz Philipp4ORCID,Wortmann Felix3ORCID,Weinmann Wolfgang1ORCID

Affiliation:

1. Institute of Forensic Medicine, Forensic Toxicology and Chemistry, University of Bern , Murtenstrasse 26, 3008 Bern, Switzerland

2. Graduate School for Cellular and Biomedical Sciences, University of Bern , Mittelstrasse 43, 3012 Bern, Switzerland

3. Institute of Technology Management, University of St. Gallen , Dufourstrasse 40a, 9000 St. Gallen, Switzerland

4. Institute of Forensic Medicine, Medical Center, University of Freiburg , Albertstraße 9, 79104 Freiburg, Germany

Abstract

Abstract Direct alcohol biomarkers are of growing interest for the assessment of alcohol consumption, with particular interest in phosphatidylethanol (PEth) in recent years. PEth is only formed when alcohol is present in the body. However, there is no statement about how much the PEth concentration increases after single moderate alcohol consumption. This study was conducted to determine the increase in PEth concentrations after a single drinking event. Additionally, a new volumetric sampling device (volumetric dried blood spot cards (DBSV)) was evaluated, which was designed to simplify further sampling processes and to allow for easy self-sampling. Dried blood samples from 31 volunteers were collected before and after single alcohol consumption with a mean maximum breath alcohol concentration of 0.4 mg/L (range: 0.30–0.55 mg/L). PEth concentrations were determined after automated extraction by liquid chromatography--tandem mass spectrometry. PEth 16:0/18:1 and PEth 16:0/18:2 concentrations increased to an average of 45 ng/mL each in patients starting below 20 ng/mL (range: 25.0–57.0 ng/mL for PEth 16:0/18:1; range 26.8–62.3 ng/mL for PEth 16:0/18:2). PEth concentrations in patients starting above 20 ng/mL increased by a mean of 30 ng/mL (range: 6.2–71.3 ng/mL for PEth 16:0/18:1; range 8.8–65.3 ng/mL for PEth 16:0/18:2). In addition, the comparison of the new sampling device DBSV with a standard filter paper card (with volumetrically applied 20 µL of blood samples) yielded a close agreement for the determined PEth concentrations in 24 forensic samples and three external controls. Therefore, the sampling device DBSV proved to be suitable for the determination of PEth concentrations in blood.

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3