Optimal primary wound closure methods after thyroid and parathyroid surgery: network meta-analysis of randomized clinical trials

Author:

Davey Matthew G1,Browne Ferdia1,Davey Martin S1ORCID,Walsh Stewart R1,Kerin Michael J1ORCID,Lowery Aoife J1

Affiliation:

1. Discipline of Surgery, The Lambe Institute for Translational Research, National University of Ireland, Galway , Galway H91 YR71 , Ireland

Abstract

Abstract Background At present, there is no consensus on optimal neck wound closure methods after thyroid and parathyroid surgery. The aim of this study was to perform a systematic review and network meta-analysis of RCTs evaluating the optimal neck closure method after thyroid and parathyroid surgery. Methods A frequentist random-effects network meta-analysis was performed for RCTs comparing at least two closure methods according to PRISMA-network meta-analysis guidelines. Analysis was performed using R packages and Shiny. Results Eighteen RCTs evaluating six closure methods (that is adhesive (28.5 per cent, 404 patients), absorbable subcuticular suture (18.1 per cent, 257 patients), non-absorbable subcuticular suture (16.8 per cent, 238 patients), staples (26.3 per cent, 372 patients), steristrips (8.1 per cent, 115 patients), and conventional suture (2.1 per cent, 30 patients)) in 1416 patients were included. At network meta-analysis, there was no difference in complication, infection, dehiscence, or haematoma rates irrespective of closure method used. Staples reduced closure duration versus absorbable subcuticular suture (mean difference (MD) 8.50, 95 per cent c.i. 6.90 to 10.10) and non-absorbable subcuticular suture (MD 0.30, 95 per cent c.i. 0.23 to 0.37), whereas adhesives (MD −1.05, 95 per cent c.i. −1.31 to −0.79) reduced closure time relative to staples. Cosmesis was improved after non-absorbable subcuticular suture (odds ratio (OR) 3.41, 95 per cent c.i. 1.66 to 7.00) relative to staples. Staples reduced patient satisfaction (OR 0.04, 95 per cent c.i. 0.00 to 0.33) and ability to shower (OR 0.04, 95 per cent c.i. 0.00 to 0.33) relative to adhesives. Conclusion Despite staples decreasing closure times, this advantage is offset by reduced patient satisfaction, ability to shower, and cosmesis compared with patients with wounds closed using adhesives, absorbable subcuticular suture, and non-absorbable subcuticular suture. Therefore, these closure methods are favourable for closing neck wounds due to more acceptable patient-reported outcomes, without compromising the safety of the procedure.

Funder

National Breast Cancer Research Institute

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3