Value of regular endosonography and [18F]fluorodeoxyglucose PET–CT after surgery for gastro-oesophageal junction, stomach or pancreatic cancer

Author:

Bjerring O S12ORCID,Hess S345,Petersen H3ORCID,Fristrup C W12,Lundell L16,Mortensen M B12

Affiliation:

1. Department of Surgery, Odense University Hospital, Odense, Denmark

2. OPAC, Odense Pancreas Centre, Odense University Hospital, Odense, Denmark

3. Department of Physiology and Nuclear Medicine, Odense University Hospital, Odense, Denmark

4. Department of Radiology and Nuclear Medicine, Hospital South West Jutland, Esbjerg, Denmark

5. Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark

6. CLINTEC, Karolinska Institutet, Stockholm, Sweden

Abstract

Abstract Background Most patients undergo follow-up after surgery for cancers of the gastro-oesophageal junction, stomach or pancreas, but data to support which modalities to use and the frequency of investigation are limited. Methods Patients in the EUFURO study were randomized to either visits to the outpatient clinic at 3, 6, 9, 12, 18, and 24 months after surgery (standard), or to the addition of [18F]fluorodeoxyglucose (FDG) PET–CT and endoscopic ultrasonography (EUS) with guided fine-needle aspiration biopsy to clinical assessments (intervention). Data from the intervention arm were used to analyse the diagnostic performance of endosonography or [18F]FDG PET–CT in detecting recurrences. Results During the scheduled follow-up, 42 of 89 patients developed recurrence; PET–CT and EUS in combination detected 38 of these recurrences. EUS detected 23 of the 42 patients with recurrent disease during follow-up and correctly diagnosed 17 of 19 locoregional recurrences. EUS was able to detect isolated locoregional recurrence in 11 of 13 patients. In five patients, EUS was false-positive for isolated locoregional recurrence owing to missed distant metastases. PET–CT detected locoregional recurrence in only 12 of 19 patients, and isolated locoregional recurrence in only 7 of 13. False-positive PET–CT results in 23 patients led to a total of 44 futile procedures. Conclusion Accuracy in detecting recurrences by concomitant use of PET–CT and EUS was high (90 per cent). PET–CT had moderate to high sensitivity for overall recurrence detection, but low specificity. EUS was superior to PET–CT in the detection of locoregional and isolated locoregional recurrences.

Funder

Danish Cancer Society

Fehr Foundation

Fionia Foundation

Region of Southern Denmark

University of Southern Denmark

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3