Defining indocyanine green fluorescence to assess anastomotic perfusion during gastrointestinal surgery: systematic review

Author:

Slooter M D1ORCID,Mansvelders M S E1,Bloemen P R2,Gisbertz S S1,Bemelman W A1,Tanis P J1,Hompes R1,van Berge Henegouwen M I1,de Bruin D M1

Affiliation:

1. Departments of Surgery, Amsterdam the Netherlands

2. Biomedical Engineering and Physics, Amsterdam University Medical Centre, University of Amsterdam, Amsterdam, the Netherlands

Abstract

Abstract Background The aim of this systematic review was to identify all methods to quantify intraoperative fluorescence angiography (FA) of the gastrointestinal anastomosis, and to find potential thresholds to predict patient outcomes, including anastomotic leakage and necrosis. Methods This systematic review adhered to the PRISMA guidelines. A PubMed and Embase literature search was performed. Articles were included when FA with indocyanine green was performed to assess gastrointestinal perfusion in human or animals, and the fluorescence signal was analysed using quantitative parameters. A parameter was defined as quantitative when a diagnostic numeral threshold for patient outcomes could potentially be produced. Results Some 1317 articles were identified, of which 23 were included. Fourteen studies were done in patients and nine in animals. Eight studies applied FA during upper and 15 during lower gastrointestinal surgery. The quantitative parameters were divided into four categories: time to fluorescence (20 studies); contrast-to-background ratio (3); pixel intensity (2); and numeric classification score (2). The first category was subdivided into manually assessed time (7 studies) and software-derived fluorescence–time curves (13). Cut-off values were derived for manually assessed time (speed in gastric conduit wall) and derivatives of the fluorescence–time curves (Fmax, T1/2, TR and slope) to predict patient outcomes. Conclusion Time to fluorescence seems the most promising category for quantitation of FA. Future research might focus on fluorescence–time curves, as many different parameters can be derived and the fluorescence intensity can be bypassed. However, consensus on study set-up, calibration of fluorescence imaging systems, and validation of software programs is mandatory to allow future data comparison.

Funder

Stryker European Operations

Publisher

Oxford University Press (OUP)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3