Evaluation of intraoperative neuromonitoring (IONM) data with the Mainz IONM Quality Assurance and Analysis tool

Author:

Musholt Thomas J1ORCID,Staubitz Julia I1ORCID,Musholt Petra B1

Affiliation:

1. Section of Endocrine Surgery, Department of General, Visceral and Transplantation Surgery, University Medical Centre, Johannes Gutenberg-University Mainz , Mainz , Germany

Abstract

Abstract Background Intraoperative neuromonitoring is widely used in thyroid and parathyroid surgery to prevent unilateral and especially bilateral recurrent nerve paresis. Reference values for amplitude and latency for the recurrent laryngeal nerve and vagus nerve have been published. However, data quality measures that exclude errors of the underlying intraoperative neuromonitoring (IONM) data (immanent software errors, false data labelling) before statistical analysis have not yet been implemented. Methods The authors developed an easy-to-use application (the Mainz IONM Quality Assurance and Analysis tool) using the programming language R. This tool allows visualization, automated and manual correction, and statistical analysis of complete raw data sets (electromyogram signals of all stimulations) from intermittent and continuous neuromonitoring in thyroid and parathyroid surgery. The Mainz IONM Quality Assurance and Analysis tool was used to evaluate IONM data generated and exported from ‘C2’ and ‘C2 Xplore’ neuromonitoring devices (inomed Medizintechnik GmbH) after surgery. For the first time, reference values for latency and amplitude were calculated based on ‘cleaned’ IONM data. Results Intraoperative neuromonitoring data files of 1935 patients consecutively operated on from June 2014 to May 2020 were included. Of 1921 readable files, 34 were excluded for missing data labelling. Automated plausibility checks revealed: less than 3 per cent device errors for electromyogram signal detection; 1138 files (approximately 60 per cent) contained potential labelling errors or inconsistencies necessitating manual review; and 915 files (48.5 per cent) were indeed erroneous. Mean(s.d.) reference onset latencies for the left vagus nerve, right vagus nerve, recurrent laryngeal nerve, and external branch of the superior laryngeal nerve were 6.8(1.1), 4.2(0.8), 2.5(1.1), and 2.1(0.5) ms, respectively. Conclusion Due to high error frequencies, IONM data should undergo in-depth review and multi-step cleaning processes before analysis to standardize scientific reporting. Device software calculates latencies differently; therefore reference values are device-specific (latency) and/or set-up-specific (amplitude). Novel C2-specific reference values for latency and amplitude deviate considerably from published values.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3