Reliability of Measurements Obtained With the Timed “Up & Go” Test in People With Parkinson Disease

Author:

Morris Susan12,Morris Meg E32,Iansek Robert4

Affiliation:

1. S Morris, MAppSc, BAppSc(PT), Grad Dip (PT), is a private practitioner in Melbourne, Victoria, Australia

2. Susan Morris and Meg Morris provided concept/research design, writing, and data analysis. Susan Morris provided data collection and project management, and Meg Morris provided fund procurement. Robert Iansek provided subjects and administrative support

3. ME Morris, PhD, MAppSc, BAppSc(PT), Grad Dip (Gerontology), is Professor and Head, School of Physiotherapy, La Trobe University, Victoria 3086, Australia.

4. R Iansek, PhD, FRACP, is Neurologist and Director, Movement Disorders Program, Kingston Centre, Cheltenham, Victoria 3192, Australia

Abstract

Abstract Background and Purpose. The Timed “Up & Go” Test (TUG) is used to measure the ability of patients to perform sequential locomotor tasks that incorporate walking and turning. This study investigated the retest reliability, interrater reliability, and sensitivity of TUG scores in detecting changes in mobility in subjects with idiopathic Parkinson disease (PD). Subjects. The performance of 12 people with PD was compared with that of 12 age-matched comparison subjects without PD. Methods. The subjects with PD completed 5 trials of the TUG after withdrawal of levodopa for 12 hours (“off” phase of the medication cycle) as well as an additional 5 trials 1 hour after levodopa was administered (“on” phase of the medication cycle). They were scored on the Modified Webster Scale at both sessions. The comparison subjects also performed 5 TUG trials. All trials were videotaped and timed by 2 experienced raters. The videotape was later rated by 3 experienced clinicians and 3 inexperienced clinicians. Results. For the subjects with PD, within-session performance was highly consistent, with correlations (r) ranging from .80 to .98 for the “off” phase and from .73 to .99 for the “on” phase. The performance of the comparison subjects across the 5 trials was also highly consistent (r=.90–.97). Comparisons showed differences between trials 1 and 2 on the TUG for both groups. Removal of data for trial 1 (the practice trial) further enhanced retest reliability. There was close agreement in TUG scores among raters despite different levels of experience (intraclass correlation coefficient [3,1]=.87–.99). Mean TUG scores were different between the “on” and “off” phases of the levodopa cycle and between subjects with PD and comparison subjects during the “on” phase. Conclusion and Discussion. Retest reliability and interrater reliability of the TUG measurements were high, and the measurements reflected changes in performance according to levodopa use. The TUG can also be used to detect differences in performance between people with PD and elderly people without PD.

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3