Hurry Up and Get Out of the Way! Exploring the Limits of Muscle-Based Latch Systems for Power Amplification

Author:

Abbott Emily M1,Nezwek Teron2,Schmitt Daniel3,Sawicki Gregory S1

Affiliation:

1. George W. Woodruff School of Mechanical Engineering and School of Biological Sciences, Georgia Institute of Technology, 801 Ferst Drive, GA, USA

2. Tufts University School of Medicine, Boston, MA USA

3. Department of Evolutionary Anthropology, Duke University, Durham, NC, USA

Abstract

Abstract Animals can amplify the mechanical power output of their muscles as they jump to escape predators or strike to capture prey. One mechanism for amplification involves muscle–tendon unit (MT) systems in which a spring element (series elastic element [SEE]) is pre-stretched while held in place by a “latch” that prevents immediate transmission of muscle (or contractile element, CE) power to the load. In principle, this storage phase is followed by a triggered release of the latch, and elastic energy released from the SEE enables power amplification (PRATIO=PLOAD/PCE,max >1.0), whereby the peak power delivered from MT to the load exceeds the maximum power limit of the CE in isolation. Latches enable power amplification by increasing the muscle work generated during storage and reducing the duration over which that stored energy is released to power a movement. Previously described biological “latches” include: skeletal levers, anatomical triggers, accessory appendages, and even antagonist muscles. In fact, many species that rely on high-powered movements also have a large number of muscles arranged in antagonist pairs. Here, we examine whether a decaying antagonist force (e.g., from a muscle) could be useful as an active latch to achieve controlled energy transmission and modulate peak output power. We developed a computer model of a frog hindlimb driven by a compliant MT. We simulated MT power generated against an inertial load in the presence of an antagonist force “latch” (AFL) with relaxation time varying from very fast (10 ms) to very slow (1000 ms) to mirror physiological ranges of antagonist muscle. The fastest AFL produced power amplification (PRATIO=5.0) while the slowest AFL produced power attenuation (PRATIO=0.43). Notably, AFLs with relaxation times shorter than ∼300 ms also yielded greater power amplification (PRATIO>1.20) than the system driving the same inertial load using only an agonist MT without any AFL. Thus, animals that utilize a sufficiently fast relaxing AFL ought to be capable of achieving greater power output than systems confined to a single agonist MT tuned for maximum PRATIO against the same load.

Publisher

Oxford University Press (OUP)

Subject

Plant Science,Animal Science and Zoology

Reference60 articles.

1. Vertical jumping in Galago senegalensis: the quest for an obligate mechanical power amplifier;Aerts;Philos Trans R Soc B Biol Sci,1998

2. Tendon elasticity and muscle function;Alexander;Comp Biochem Physiol A Mol Integr Physiol,2002

3. Optimal shortening velocity (V/Vmax) of skeletal muscle during cyclical contractions: length–force effects and velocity-dependent activation and deactivation;Askew;J Exp Biol,1998

4. Evidence for a vertebrate catapult: elastic energy storage in the plantaris tendon during frog jumping;Astley;Biol Lett,2012

5. Geared up to stretch: pennate muscle behavior during active lengthening;Azizi;J Exp Biol,2014

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3