Perpendicular drill bit alignment provides a practical guidance to determine the appropriate suture anchor insertion angle during acetabular labral repair

Author:

Ismailoglu Abdul Veli1ORCID,Ozdogmus Omer2,Karaman Muhammed Ilkay3,Kayaalp Asim4,Kocaoglu Baris3

Affiliation:

1. Department of Anatomy, Faculty of Medicine, Acibadem Mehmet Ali Aydinlar University, Kayisdagi Cad. No: 32, Atasehir, Istanbul 34752, Turkey

2. Department of Anatomy, Faculty of Medicine, Marmara Univesity, Maltepe Basibuyuk Yolu, No: 9, Maltepe, Istanbul 34854, Turkey

3. Department of Orthopedic Surgery, Faculty of Medicine, Acibadem Mehmet Ali Aydinlar University, Kayisdagi Cad. No: 32, Atasehir, Istanbul 34752, Turkey

4. Department of Orthopedic Surgery, Ankara Cankaya Hospital, Barbaros Sk. No: 44, Cankaya, Ankara 06700, Turkey

Abstract

ABSTRACT The safe acetabular rim angle is an anatomical measurement used to determine the safety margin when inserting suture anchors. The purpose of the present study was to find out whether aligning the drill bit perpendicularly during arthroscopic surgery can provide a reference point for determining an appropriate angle to facilitate the suture anchor insertion and to prevent extra- and intra-articular perforations. One hundred computed tomographic hips were used to reconstruct three-dimensional acetabular hip models. Each model was radially sectioned at the 4 o’clock, 3 o’clock and anterior inferior iliac spine (AIIS) positions (that corresponded mainly to the 2:20 clock position). A perpendicular reference line, representing a perpendicular drill bit alignment, was drawn for each position within the acetabular model, and its relation to the safe acetabular rim angle was measured. The length of the perpendicular reference line and the effect of gender on measurements were also evaluated. The mean safe acetabular rim angle at the 3 o’clock position was significantly smaller compared to other clock positions (P < 0.001). The perpendicular reference line was located out of the safe acetabular rim angle in 28 cases (%28), mostly in female acetabula at the 3 o’clock position, and relative to the perpendicular reference line the required minimal angle was 4° ± 2.3° to place the anchor in the safe acetabular rim angle to avoid extra-articular perforation. The perpendicular reference line was shortest at the 3 o’clock position, and its mean length was shorter in female acetabula at all clock positions (P < 0.001). Aligning the drill bit perpendicular to the acetabular opening plane during an arthroscopic anchor placement is a practical way to estimate and target the position of the safe acetabular rim angle to avoid anchor perforations. Based on measurements from a perpendicularly aligned drill bit, the drill bit should be directed towards the joint minimally by 4° to avoid extra-articular perforations and maximally by 30° to avoid intra-articular perforations.

Funder

Türkiye Bilimsel ve Teknolojik Arastirma Kurumu

Acibadem Mehmet Ali Aydinlar University

Publisher

Oxford University Press (OUP)

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3