The hip asphericity angle: a novel angle for measurement of Cam-FAI correction

Author:

Masoud Mohammad12ORCID,Apivatgaroon Adinun3ORCID,Said Hatem1,Abdel-Hamid Mohamed M1,El-Assal Maher1,Dienst Michael4

Affiliation:

1. Orthopedics and Trauma Department, Assiut University, University Street, Assiut 71515, Egypt

2. Department of Traumatology, Kreiskrankenhaus, Spitalstr. 25, Lörrach 79539, Germany

3. Department of Orthopedics, Faculty of Medicine, Thammasat University, 99/209 Khlong-Neung Sub-District, Khlong-Luang district, Pathumthani 12120, Thailand

4. Orthopädische Chirurgie München (OCM), Steinerstr. 6, Munich 81369, Germany

Abstract

Abstract The alpha angle is routinely used for the diagnosis and quantitative description of the Cam deformity of the hip. However, a reliable identification of the femoral neck axis as its reference line can be difficult. Moreover, most cam resections include a reduction of the femoral neck diameter with an automatic posteromedial angulation of the femoral neck axis. In consequence, the reference axes for the pre- and postoperative alpha angles are different, and a comparison of both angles underlies a systematic error to relatively higher postoperative alpha angles. In order to avoid this systemic error, we propose the hip asphericity (HA) angle with a reference axis independent of the amount of bony resection. Two retrospective groups were formed, a ‘femoroacetabular impingement (FAI) group’ that had hip arthroscopy for cam resection and a ‘Control group’ without cam deformity. The alpha and HA angles were measured by three examiners. The measurements were repeated 1 month later. In the FAI group, offset correction was calculated using both angles. Statistically significant differences for both the alpha and the HA angles were found between the control and the preoperative FAI group as well as between the preoperative and postoperative FAI groups. The HA angle-correction by a mean of 27.5° was significantly higher in comparison to the alpha angle correction by a mean of 25.4°. The intertester and intratester reliability of both angles were not significantly different. The HA angle is a new and reliable radiographic parameter for measuring cam deformity and proves superior in measuring cam correction.

Publisher

Oxford University Press (OUP)

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3