Use of a larger surface area tip on bipolar radiofrequency wands in hip arthroscopy is associated with significantly lower traction and total surgery times

Author:

Wininger Austin E1ORCID,Aflatooni Justin O1,Harris Joshua D1ORCID

Affiliation:

1. Houston Methodist Orthopedics and Sports Medicine, Outpatient Center, 6445 Main Street, Suite 2500, Houston, TX 77030, USA

Abstract

ABSTRACT Clinical outcomes in arthroscopic hip preservation surgery have improved over the past two decades due to many factors, including advancements in technique and instrumentation. Complications following hip arthroscopy are associated with increased traction and overall surgical times. The purpose of this study was to compare traction and surgical times during hip arthroscopy using two different radiofrequency ablation wands produced by the same manufacturer. The authors hypothesized that the wand with a larger surface area would result in significantly less traction and surgical times. This study was a retrospective comparative investigation on patients who underwent arthroscopic surgery of the central, peripheral, peritrochanteric and/or deep gluteal space compartments of the hip. Both wands are 50-degree-angled probes, but the tip and shaft diameters are 3 and 3.75 mm for Wand A (Ambient Super MultiVac 50; tip surface area 7.1 mm2) compared to 4.7 and 4.7 mm for Wand B (Ambient HipVac 50; tip surface area 17.3 mm2), respectively. There was no difference (P = 0.16) in mean age of Wand A patients (30 females, 20 males; 35.2 years) versus Wand B patients (31 females, 19 males; 32.7 years). Traction time was significantly less in the Wand B group (41 ± 6 versus 51 ± 18 min; P < 0.001), as was surgical time (102 ± 13 versus 118 ± 17 min; P < 0.001). There were no significant differences in the number of labral anchors used or Current Procedural Terminology codes performed between groups. In conclusion, it was observed that the use of a larger surface area wand was associated with significantly less traction and surgical times during hip arthroscopy.

Publisher

Oxford University Press (OUP)

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3