Determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on Lequesne’s false-profile radiograph and on computed tomography

Author:

Cheng Hui12,Zhang Liqiang13ORCID,Luo Dianzhong2,Ren Ningtao2,Zhang Zhendong2,Gu Wang2,Hu Yongcheng14,Zhang Hong2ORCID

Affiliation:

1. Graduate School, Tianjin Medical University , No. 22, Qiaotai Road, Heping District, Tianjin, China

2. Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital , No. 51, Fucheng Road, Haidian District, Beijing, China

3. Department of Orthopaedics, Shanxi Children’s Hospital , No. 65, Jinxi Street, Jinyuan District, Shanxi, Taiyuan, China

4. Department of Bone and Soft Tissue Oncology, Tianjin Hospital , No. 406, Jiefang South Road, Hexi District, Tianjin, China

Abstract

ABSTRACT Anterior hip coverage is important for hip stability. As a parameter of anterior hip coverage, the anterior center-edge angle on false-profile radiograph (ACEA FP) is associated with clinical outcomes. With the widespread application of computed tomography (CT), the anterior center-edge angle on CT (ACEA CT) has also been used to measure anterior hip coverage. Little is known about the reproducibility of the ACEA FP and ACEA CT in patients with hip dysplasia or the correlation between the ACEA CT and ACEA FP. In total, 49 hips of 49 patients who underwent periacetabular osteotomy in our center were included. The lateral center-edge angle, Tönnis angle, ACEA FP and ACEA CT were determined. We assessed the intraobserver and interobserver reliability of the ACEA FP and ACEA CT, the effect of the Tönnis angle on the reliability of the ACEA FP and ACEA CT and the correlation between the ACEA CT and ACEA FP. The intraobserver and interobserver interclass correlation coefficients of the ACEA FP were good, and those of the ACEA CT were very good. The Tönnis angle was weakly correlated with inconsistent ACEA FP measurements (P = 0.008) but not with inconsistent ACEA CT measurements (P = 0.600). No correlation between ACEA FP and ACEA CT measurements was observed (P = 0.213–0.665). The reproducibility of the ACEA CT is more consistent than that of the ACEA FP. The oblique acetabular roof had an effect on determining the ACEA FP but not on determining the ACEA CT. No correlation was observed between the measured ACEA FP and ACEA CT values, so the clinical evidence obtained from the ACEA FP cannot be directly applied to the ACEA CT.

Publisher

Oxford University Press (OUP)

Subject

General Earth and Planetary Sciences,General Environmental Science

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3