Effect of absolute blood volume measurement–guided fluid management on the incidence of intradialytic hypotension-associated events: a randomised controlled trial

Author:

Jongejan Micha12ORCID,Gelinck Armin1,van Geloven Nan3,Dekker Friedo W4,Vleming Louis Jean1

Affiliation:

1. Department of Nephrology, HagaZiekenhuis , The Hague , The Netherlands

2. Department of Internal Medicine, Leiden University Medical Center , Leiden , The Netherlands

3. Department of Biomedical Data Sciences, Leiden University Medical Center , Leiden , The Netherlands

4. Department of Clinical Epidemiology, Leiden University Medical Center , Leiden , The Netherlands

Abstract

Abstract Background Ultrafiltration to target weight during haemodialysis is complicated by intradialytic hypotension-associated adverse events (IHAAEs) in 10–30% of dialysis treatments. IHAAEs are caused by critical reductions in absolute blood volume (ABV), due to the interaction of ultrafiltration, refill and compensatory mechanisms. Non-randomised studies have suggested that ABV-guided treatment, using an indicator dilution technique employing the blood volume monitor on the dialysis machine, could reduce the incidence of IHAAEs. Methods We performed an open-label randomised controlled trial. Patients were randomly assigned to adjustment of target weight guided by ABV measurements or standard care. The primary outcome was the change in the incidence of IHAAEs from baseline, defined as the percentage of treatment episodes in a 4-week period where the patient had a systolic blood pressure <90 mmHg or symptoms of impending hypotension. ABV measurements were compared with anthropomorphometric estimation and the gold standard using isotope dilution. Results A total of 56 patients were randomised, of whom 29 were allocated to ABV-guided treatment and 27 to standard care. Overall baseline incidence of IHAAEs was 26.0%. ABV-guided treatment significantly reduced the incidence of IHAAEs compared with standard care, with a mean change from baseline of −9.6% [95% confidence interval (CI) −17.3 to −1.8) versus 2.4% (95% CI −2.3–7.2). The adjusted difference between the groups was 10.5% (95% CI 1.3–19.8; P = .026). ABV measurement had moderate agreement with other methods to estimate blood volume. The sensitivity for the previously suggested threshold of a post-dialysis normalised blood volume of 65 ml/kg was observed to be 74% in this study. Conclusions ABV-guided volume management significantly reduced IHAAEs compared with standard care. The clinical relevance of the previously suggested threshold of 65 ml/kg cannot be firmly concluded on the basis of our results. If confirmed in a larger trial, this intervention could potentially change dialysis practice and impact patient care in a clinically meaningful way.

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3