3D Exoscope System in Neurosurgery—Comparison of a Standard Operating Microscope With a New 3D Exoscope in the Cadaver Lab

Author:

Herlan Stephan12,Marquardt Jakob S3,Hirt Bernhard2,Tatagiba Marcos1,Ebner Florian H1

Affiliation:

1. Department of Neurosurgery, Eberhard Karls University of Tübingen, Tübingen, Germany

2. Institute of Clinical Anatomy and Cell Analysis, Eberhard Karls University of Tübingen, Tübingen, Germany

3. Department of Neurosurgery, Asklepios Klinik Nord, Heidberg, Hamburg, Germany

Abstract

Abstract BACKGROUND For decades, the operating microscope has been the “gold standard” visualization device in neurosurgery. The development of endoscopy revolutionized different surgical disciplines, whereas in neurosurgery, the endoscope is commonly used as an additional device more than as single visualization tool. Invention of a 3D exoscope system opens new possibilities in visualization and ergonomics in neurosurgery. OBJECTIVE To assess the prototype of a 3D exoscope (3D exoscope, year of manufacture 2015, FA Aesculap, Tüttlingen, Germany) as neurosurgical visualization device in comparison to a standard operating microscope. METHODS A pterional approach was performed in 3 ETOH-fixed specimens (6 sides). A standard operating microscope was compared to a 3D exoscope prototype. Dimensions like visual field, magnification, illumination, ergonomics, depth effect, and 3D impression were compared. RESULTS In all approaches, the structures of interest could be clearly visualized with both devices. Magnification showed similar results. The exoscope had more magnification potential, whereas the visual quality got worse in higher magnification levels. The illumination showed better results in the microscope. Surgeons felt more comfortable with the 3D exoscope, concerning ergonomic considerations. Depth effect and 3D impression showed similar results. None of the surgeons felt uncomfortable using the exoscope. CONCLUSION The operating microscope is the gold standard visualization tool in neurosurgery because of its illumination, stereoscopy, and magnification. Nevertheless, it causes ergonomic problems. The prototype of a 3D exoscope showed comparable features in visual field, stereoscopic impression, and magnification, with a clear benefit concerning the ergonomic possibilities.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3