Scapular Muscle Tests in Subjects With Shoulder Pain and Functional Loss: Reliability and Construct Validity

Author:

Michener Lori A1,Boardman N Douglas2,Pidcoe Peter E3,Frith Angela M4

Affiliation:

1. LA Michener, PT, PhD, ATC, SCS, is Assistant Professor, Department of Physical Therapy, Room 100, West Hospital Basement, Virginia Commonwealth University–Medical College of Virginia Campus, Richmond, VA 23298 (USA)

2. ND Boardman, MD, is Assistant Professor, Department of Orthopaedic Surgery, Virginia Commonwealth University–Medical College of Virginia Campus

3. PE Pidcoe, PT, PhD, is Assistant Professor, Department of Physical Therapy, Virginia Commonwealth University–Medical College of Virginia Campus

4. AM Frith, PT, DPT, is Staff Physical Therapist, Southside Rehabilitation Services, Colonial Heights, Va

Abstract

Abstract Background and Purpose. Scapular muscle performance evaluated with a handheld dynamometer (HHD) has been investigated only in people without shoulder dysfunction for test-retest reliability of data obtained with a single scapular muscle test. The purpose of this study was to assess the reliability, error, and validity of data obtained with an HHD for 4 scapular muscle tests in subjects with shoulder pain and functional loss. Subjects and Methods. Subjects (N=40) with shoulder pain and functional loss were tested bymeasuring the kilograms applied with an HHD during 3 trials for muscle tests for the lower trapezius, upper trapezius, middle trapezius, and serratus anterior muscles. Concurrently, surface electromyography (sEMG) data were collected for the 4 muscles. The same procedures were performed 24 to 72 hours after the initial testing by the same tester. Muscle tests were performed 3 times, and the results were averaged for data analysis. Results. Intraclass correlation coefficients for intratester reliability of measurements of isometricforce obtained using an HHD ranged from .89 to .96. The standard error of the measure (90% confidenceinterval [CI]) ranged from 1.3 to 2.7 kg; the minimal detectable change (90% CI) ranged from 1.8 to 3.6 kg. Construct validity assessment, done by comparing the amounts of isometric muscle activity (sEMG) for each muscle across the 4 muscle tests, revealed that the muscle activity of the upper trapezius and lower trapezius muscles washighest during their respective tests. Conversely, the isometric muscle activity of the middle trapezius and serratus anterior muscles was not highest during their respective tests. Discussion and Conclusion. In people with shoulder pain and functional loss, the intrarater reliability and error over 1 to 3 days were established using an HHD for measurement of isometric force for the assessment of scapular muscle performance. Error values can be used to make decisions regarding individual patients. Construct validity was established for the lower and upper trapezius muscle tests; therefore, these tests are advocated for use. However, construct validity was not demonstrated for the serratus anterior and middle trapezius muscle tests as performed in this study. Further investigation of these muscle tests is warranted.

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3