SURVEY OF COMPUTED TOMOGRAPHY PRACTICE IN UKRAINE AND ESTABLISHMENT OF NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR MOST COMMON CT EXAMINATIONS OF ADULTS

Author:

Stadnyk Larysa1,Nosyk Olga1,Tonkopi Elena2ORCID,Boguslavska Alexandra3,Vassileva Jenia45

Affiliation:

1. Central Laboratory of Radiation Safety and Dosimetry of Medical Exposure, Grigorev Institute for Medical Radiology and Oncology , 82 Pushkinska Street, Kharkiv 61024 , Ukraine

2. Department of Diagnostic Radiology, Dalhousie University , PO BOX 9000, 1276 South Park Street, Halifax, NS B3H 2Y9 , Canada

3. State Nuclear Regulatory Inspectorate of Ukraine , 9/11 Arselna Street, Kyiv 01001 , Ukraine

4. Radiation Protection of Patients Unit , International Atomic Energy Agency, , PO Box 100, Vienna 1400 , Austria

5. Vienna International Centre , International Atomic Energy Agency, , PO Box 100, Vienna 1400 , Austria

Abstract

Abstract This study reports results of the first nationwide survey of computed tomography (CT) practice in Ukraine and proposed national diagnostic reference levels (DRLs) for common CT examinations. The collected data included characteristics of CT scanners, frequency of CT exams per anatomical region, dose indices CTDIvol and dose-length product (DLP). National DRLs were proposed at the 75th percentile of median dose indices distributions for four common CT protocols: head without contrast (brain examinations for stroke and trauma), routine chest without contrast, single-phase contrast-enhanced CT of abdomen and pelvis and oncology protocol (chest–abdomen–pelvis). The results showed 4- to 9-fold variations of median dose indices between CT scanners for the same type of examination. The following values of the CTDIvol and DLP were proposed as national DRLs: 59 mGy and 1130 mGy•cm for head, 14 mGy and 492 mGy•cm for chest, 22 mGy and 845 mGy•cm for abdomen/pelvis and 2120 mGy•cm for oncological protocol.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3