Analysis of EURADOS neutron intercomparison results according to new ISO standards criteria

Author:

Chevallier M-A1ORCID,Fantuzzi E2,Hajek M3ORCID,Mayer S4ORCID,Tanner R5,Thomas D J6,Vanhavere F7

Affiliation:

1. Institut de Radioprotection et de Sûreté Nucléaire Dosimetry Research Department, , 92260 Fontenay-aux-Roses, France

2. Radiation Protection Institute, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) , 40136 Bologna, Italy

3. Transport and Waste Safety, International Atomic Energy Agency (IAEA) Division of Radiation, , 1400 Vienna, Austria

4. Paul Scherrer Institute (PSI) Department of Radiation Safety and Security, , CH-5232 Villigen, Switzerland

5. UK Health Security Agency (UKHSA) Dosimetry Services Department, , Didcot, Oxon OX11 0RQ, UK

6. National Physical Laboratory (NPL) Nuclear Metrology Group, , Teddington TW11 0LW, UK

7. SCK-CEN, Belgian Nuclear Research Centre Radiation Protection Dosimetry and Calibration, , 2400 Mol, Belgium

Abstract

Abstract The European Radiation Dosimetry Group has carried out several different types of intercomparison (IC) exercises in the past that qualify as proficiency tests for different dosimetry systems and types of radiation. The first neutron dosemeter IC was held in 2012 (IC2012n) and was followed by a second in 2017/2018 (IC2017n). In sum, 31 Individual Monitoring Services (IMSs) entered 34 dosimetry systems in IC2012n, and 32 IMSs entered 33 dosimetry systems for IC2017n. Such exercises provided a rare opportunity to see how neutron dosemeters perform. For the IC2012n exercise, there were no applicable performance standards for neutron personal dosemeters. ISO/TC85/SC2 updated the ISO Standard 14146 in 2018 (ISO 14146:2018. Radiation protection—Criteria and performance limits for the periodic evaluation of dosimetry services) to include neutron dosimetry. It was thus possible to analyse the IC2017n exercise in accordance with the requirements given by this new standard. It is now of interest to reanalyse the results of IC2012n to quantify any modifications to the conclusions.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference19 articles.

1. Radiation protection—criteria and performance limits for the periodic evaluation of dosimetry services;International Oragnization of Standardization. ISO 14146:2018

2. EURADOS intercomparison 2012 for neutron dosemeters;Fantuzzi;Eur. Radiat. Dosim.,2014

3. EURADOS IC2012n: EURADOS 2012 intercomparison for whole-body neutron dosimetry;Fantuzzi;Radiat. Prot. Dosim.,2014

4. EURADOS IC2012n: further information derived from a EURADOS International Comparison of Neutron Personal Dosemeters;Chevallier;Radiat. Prot. Dosim.,2016

5. EURADOS intercomparison 2017 for neutron dosemeters (EURADOS Report No. 2021-06);Mayer;Eur. Radiat. Dosim.,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献