ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC ABDOMINAL-PELVIS AND CHEST-ABDOMINAL-PELVIS COMPUTED TOMOGRAPHY IN MOROCCO: SUGGESTS THE NEED FOR IMPROVED OPTIMIZATION EFFORTS

Author:

Benmessaoud Mounir1,Dadouch Ahmed1,Maghnouj Abdelmajid1,Lemmassi Assiya2,Tahiri Maroine3,El-ouardi Youssef1,Ait Ouaggou Ibrahim4

Affiliation:

1. Sidi Mohamed Ben Abdellah University, Faculty of Sciences Dhar EL Mahraz , Fez , Morocco

2. Sidi Mohamed Ben Abdellah University, Higher School of Technology , Fez , Morocco

3. Hassan First University, Higher Institute of Health Sciences , Settat , Morocco

4. University Mohammed First, National School of Applied Sciences , Oujda , Morocco

Abstract

Abstract The purpose of the current study was to derive the local diagnostic reference levels (LDRLs) for paediatric abdominal-pelvis (AP) and chest-abdominal-pelvis (CAP) computed tomography in Morocco. The data were gathered retrospectively from two hospitals for 6 months. The LDRLs were defined by volume CT dose index (CTDIvol), dose-length product (DLP) per sequence, DLP per procedure and size-specific dose estimates (SSDE). The SSDE assessment was based on the effective diameters of patients scanned. A total of 630 CT examinations were collected involving 324 AP and 306 CAP scans. The proposed LDRLs for AP, in terms of CTDIvol (mGy), were 6.9, 8.5, 8.5 and 8.5 for < 1, 1 to < 5, 5 to < 10 and 10 to < 15 y age groups, respectively. In terms of DLP (mGy.cm) per procedure, they were 436.3, 534.5, 687.9 and 961.7. In terms of SSDE (mGy), thet were 16.73, 16.83, 17.5 and 15.8 for < 1, 1 to < 5, 5 to < 10 and 10 to < 15 y, respectively. The corresponding LDRLs for CAP, in terms of CTDIvol (mGy), were 7.3, 7.3, 7.3 and 10.35. In terms of DLP (mGy.cm) per procedure, they were 531, 622.5, 705 and 936. In terms of SSDE (mGy), they were 16.22, 15.05, 14.47 and 15.2, respectively, for the four age groups. The derived dose levels were mostly higher than those found in other studies, which demonstrates the need for dose optimization and paediatric protocol standardization as well as the timeliness of the intent to establish not only local DRLs but national ones in the near future.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference40 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3