Establishment of Hp(3) calibration system for eye dose monitoring in Taiwan

Author:

Wu Chiao-An1,Chiu Min-Chi1,Huang Tseng-Te1,Lin Yi-Chun1,Chu Chien-Hau1

Affiliation:

1. Institute of Nuclear Energy Research Health Physics Division, , Taoyuan 325207, Taiwan

Abstract

Abstract In response to the ICRP’s amending the occupational exposure limit for the eye lens, the Institute of Nuclear Energy Research (INER) established the Hp(3) calibration system for eye dose monitoring in Taiwan to accurately assess the dose received in the eye lens. INER employed the narrow-spectrum series radiation according to the ISO 4037 as the X-ray radiation qualities, and the measured half-value layer consistent with a 5% difference. The air kerma rate standard was determined by the self-made free air chamber, and through dose conversion coefficient referring to ISO 4037 to obtain the Hp(3) on an ISO cylinder phantom. Furthermore, the calibration system was provided as the characteristics tests for DOSIRIS headset dosemeters. Finally, the Hp(3) calibration system has been established in Taiwan, and it can be used to provide calibration services for eye lens dosemeters and be applied to the proficiency testing that will be held in 2023.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference14 articles.

1. ICRP statement on tissue reactions/early and late effects of radiation in normal tissues and organs–threshold doses for tissue reactions in a radiation protection context;International Commission on Radiological Protection;Ann. ICRP,2012

2. Staff eye lens dose in interventional radiology and cardiology in Finland;Pekkarinen;Phys. Med.,2022

3. Occupational exposure to the whole body, extremities and to the eye lens in interventional radiology in Poland, as based on personnel dosimetry records at IFJ PAN;Szumska;Radiat. Phys. Chem.,2014

4. A multicenter study of radiation doses to the eye lenses of medical staff performing non-vascular imaging and interventional radiology procedures in Japan;Matsubara;Phys. Med.,2020

5. Eye lens dose of medical personnel involved in fluoroscopy and interventional procedures at a Malaysian hospital;Wong;Phys. Med.,2019