Dose indices of kilovoltage cone beam computed tomography for various image guided radiotherapy protocols

Author:

Gazdag-Hegyesi Szilvia12,Gáldi Ádám13,Major Tibor13,Pesznyák Csilla12

Affiliation:

1. National Institute of Oncology Center of Radiotherapy, , Budapest, Hungary

2. Budapest University of Technology and Economics Institute of Nuclear Techniques, , Budapest, Hungary

3. Semmelweis University Department of Oncology, , Budapest, Hungary

Abstract

Abstract Varian Halcyon (HA) linear accelerators (LINAC) require kilovoltage cone-beam computed tomography (CT) acquisition for all patients before all treatment fractions. The aim of this study is to compare dose indices of various available protocols with different calculation and measurement methods. CT dose index (CTDI) in mGy is a measure of the radiation dose output of a CT scanner. A pencil ionisation chamber was used to measure dose index free air and in a standard CTDI phantom for different imaging protocols of HA and TrueBeam LINACs. For the point measurements, we found large deviations between displayed and calculated low CTDI values: 26.6 and 27.1% at Head low dose and Breast protocol, respectively. The calculated values were always larger than the displayed ones for all protocols and measurement setups. For the point measurements similar results were found as in the international literature, where the displayed values the measured CTDIs.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference25 articles.

1. Measurement of dose exposure of image guidance in external beam accelerated partial breast irradiation: evaluation of different techniques and linear accelerators;Stelczer;Phys. Med.,2019

2. Initial experience with image-guided and intensity-modulated postoperative radiotherapy of gynecological cancer;Király;Magy. Onkol.,2018

3. Applications of linac-mounted kilovoltage cone-beam computed tomography in modern radiation therapy: a review;Srinivasan;Pol. J. Radiol.,2014

4. Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction, AAPM Report No. 180;American Association of Physics in Medicine,2018

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3