Affiliation:
1. College of Medicine & Health Sciences Sultan Qaboos University, , Muscat , Oman
2. Sultan Qaboos University Hospital , Radiology and Molecular Imaging, Muscat , Oman
3. College of Science Sultan Qaboos University, , Muscat , Oman
4. Royal Hospital Radiology Department, , PO. Box 1331, Muscat , Oman
Abstract
Abstract
This study aimed to estimate diagnostic reference levels (DRLs) for the most frequent computed tomography (CT) imaging examinations to monitor and better control radiation doses delivered to patients. Seven CT imaging examinations: Head, Chest, Chest High Resolution (CHR), Abdomen Pelvis (AP), Chest Abdomen Pelvis (CAP), Kidneys Ureters Bladder (KUB) and Cardiac, were considered. CT dosimetric quantities and patient demographics were collected from data storage systems. Local typical values for DRLs were calculated for CTDIvol (mGy), dose length product (DLP) (mGy·cm) and effective doses (mSv) were estimated for each examination.
The calculated DRLs were given as (median CTDIvol (mGy):median DLP (mGy·cm)): Head: 39:657; Chest: 13:451; CHR: 6:228; AP: 12:578; CAP: 20:807; KUB: 7:315, and Cardiac: 2:31. Estimated effective doses for Head, Chest, CHR, AP, CAP, KUB and Cardiac were 1.3, 12.7, 6.3, 12.5, 18.1, 5.8 and 0.8 mSv, respectively. The estimated DRLs will act as guidance doses to prevent systematic excess of patient doses.
Publisher
Oxford University Press (OUP)
Subject
Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献