COMPARISON OF RADON EXHALATION RATE MEASUREMENTS ON REFERENCE DEVICE IN OPEN AND CLOSED LOOP BY ALPHAGUARD IN FLOW-THROUGH MODE

Author:

Liu Shuaibin1ORCID,Lin Fen2,Fan Zhongkai3ORCID,Hu Tao2,Mo Yixiang2,Yuan Shuai2,Xie Ruomei2,Li Huiying2,Sun Jiale2,Yi Haibo2,Cheng Linquan2,Liu Zhipeng2,Wu Jiulin2,Zhang Xinyi2,Yuan Hongzhi2,Tan Yanliang2

Affiliation:

1. College of Physics and Electronic Engineering, Hengyang Normal University , Hengyang, Hunan Province 421008 , China

2. College of Physics and Electronic Engineering , Hengyang Normal University, Hengyang, Hunan Province 421008,   China

3. School of Nuclear Science and Technology, University of South China , Hengyang, Hunan Province 421001 , China

Abstract

Abstract Radon-222 (Rn-222) exhalation rate is vital for estimating radiation risk from many kinds of materials. AlphaGUARD measures the radon concentration based on the ionization chamber principle, which is currently recognized as a reference instrument to measure radon. In China, measurements of radon exhalation rate are performed by AlphaGUARD operated in flow-through mode on a reference device to verify measurement accuracy. These measurements are performed in both open and closed loop. AlphaGUARD can fast rapidly the variation of the radon concentration in the chamber, which is tightly pressed against the surface of the medium to accumulate the exhaled radon. When the model is used to obtain the radon exhalation rate, the radon exhalation rates obtained by nonlinear data fitting on the measured radon concentrations are similar to the reference value of the device. The difference of radon exhalation rate values of six measurements is small.

Funder

Hengyang Science and Technology Planning Project

Postgraduate Scientific Research Innovation Project of Hunan Province

Hunan Provincial Innovation Foundation for Postgraduate

National Natural Science Foundation of China

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3