A multifaceted approach in leveraging electronic health record tools for safe inpatient use of concentrated U-500 insulin

Author:

Willner Marc A1,Ketz Jeffrey1,Davis Ramona A1,Yaniv Angela W1,Bulgar-Grozav Alina1,Wang Weishi1,Shah Sneha1,Pang Bob1,Hesketh Alexandria1

Affiliation:

1. Cleveland Clinic, Cleveland, OH, USA

Abstract

Abstract Purpose The Institute for Safe Medication Practices classifies subcutaneous insulin as a high-risk medication. Concentrated U-500 insulin carries additional risks in comparison to conventional U-100 insulin, as the 5-fold more concentrated nature of this product, limitations to insulin pen dosing, and various devices for dose measurement may lead to miscommunication of patient-reported doses, resulting in downstream errors in ordering, verification, or administration. We describe a multifaceted approach to leveraging technical tools within the electronic health record (EHR) for U-500 insulin use. Summary At Cleveland Clinic, the U-500 insulin use process evolved in a number of phases using EHR tools. Phase 1 included new clinical decision support and documentation tools during order entry, including a customized alert that fired during order entry recommending that the prescriber order a consult with endocrinology and requiring the prescriber to provide the patient’s home insulin measuring device and the source of the patient’s reported home dose. In order verification, a customized alert fired directing the pharmacist to contact the patient or patient’s nurse and validate the information provided by the prescriber. Phase 2 involved transitioning dispensing of patient-specific doses from tuberculin syringes to U-500 insulin syringes. Phase 3 transitioned to use of U-500 insulin pens and included automatic dose rounding of ordered doses down to the nearest 5 units, and an additional customized pharmacist alert intended for cost conservation was added to fire if the patient had a recent administration of U-500 insulin documented, directing the pharmacist to determine whether the nurse needed a new pen dispensed. Conclusion Cleveland Clinic successfully implemented customized tools and processes within the EHR pertaining to the prescribing, verification, dispensing, and administration of U-500 insulin.

Publisher

Oxford University Press (OUP)

Subject

Health Policy,Pharmacology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Practice-enhancing publications about the medication-use process in 2022;American Journal of Health-System Pharmacy;2024-05-10

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3