Affiliation:
1. Department of General Surgery, Aberdeen Royal Infirmary, NHS Grampian, Aberdeen, UK
Abstract
Abstract
Background
Intraoperative nerve monitoring (IONM) is used increasingly in thyroid surgery to prevent recurrent laryngeal nerve (RLN) injury, despite lack of definitive evidence. This study analysed the United Kingdom Registry of Endocrine and Thyroid Surgery (UKRETS) to investigate whether IONM reduced the incidence of RLN injury.
Methods
UKRETS data were extracted on 28 July 2018. Factors related to risk of RLN palsy, such as age, sex, retrosternal goitre, reoperation, use of energy devices, extent of surgery, nodal dissection and IONM, were analysed. Data with missing entries for these risk factors were excluded. Outcomes of patients who had preoperative and postoperative laryngoscopy were analysed.
Results
RLN palsy occurred in 4.9 per cent of thyroidectomies. The palsy was temporary in 64.6 per cent and persistent in 35.4 per cent of patients. In multivariable analysis, IONM reduced the risk of RLN palsy (odds ratio (OR) 0.63, 95 per cent confidence interval (CI) 0.54 to 0.74, P < 0.001) and persistent nerve palsy (OR 0.47, 0.37 to 0.61, P < 0.001). Outpatient laryngoscopy was also associated with a reduced incidence of RLN palsy (OR 0.50, 0.37 to 0.67, P < 0.001). Bilateral RLN palsy occurred in 0.3 per cent. Reoperation (OR 12.30, 2.90 to 52.10, P = 0.001) and total thyroidectomy (OR 6.52, 1.50 to 27.80; P = 0.010) were significantly associated with bilateral RLN palsy.
Conclusion
The use of IONM is associated with a decreased risk of RLN injury in thyroidectomy. These results based on analysis of UKRETS data support the routine use of RLN monitoring in thyroid surgery.
Publisher
Oxford University Press (OUP)
Cited by
26 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献