Diagnostic accuracy using low-dose versus standard radiation dose CT in suspected acute appendicitis: prospective cohort study

Author:

Haijanen Jussi12,Sippola Suvi123,Tammilehto Ville4,Grönroos Juha12,Mäntyoja Siiri12,Löyttyniemi Eliisa5,Niiniviita Hannele46,Salminen Paulina12ORCID

Affiliation:

1. Division of Digestive Surgery and Urology, Turku University Hospital, Turku, Finland

2. Department of Surgery, University of Turku, Turku, Finland

3. Department of Surgery, Jyväskylä Central Hospital, Jyväskylä, Finland

4. Department of Radiology, Medical Imaging Centre of Southwest Finland, Turku University Hospital, Turku, Finland

5. Department of Biostatistics, University of Turku, Turku, Finland

6. Department of Medical Physics, Turku University Hospital, Turku, Finland

Abstract

Abstract Background Contrast-enhanced CT is the reference standard used in diagnostic imaging for acute appendicitis in adults. The radiation dose has been of concern. This study aimed to assess whether a lower radiation dose would affect the diagnostic accuracy of CT. Methods This was a prospective single-centre cohort study of patients (aged over 16 years) with suspected appendicitis evaluated for enrolment in concurrent APPAC II–III trials. The diagnostic accuracy of contrast-enhanced low- and standard-dose CT was compared with study protocols guiding imaging based on BMI; this enabled direct CT imaging comparison only in patients with a BMI below 30 kg/m2. The on-call CT diagnosis was compared with the final clinical diagnosis. Results Among all 856 patients investigated, the accuracy of low-dose (454 patients) and standard-dose (402 patients) CT in identifying patients with and without appendicitis was 98·0 and 98·5 per cent respectively. In patients with a BMI under 30 kg/m2, respective values were 98·2 per cent (434 patients) and 98·6 per cent (210 patients) (P = 1·000). The corresponding accuracy for differentiating between uncomplicated and complicated acute appendicitis was 90·3 and 87·6 per cent in all patients, and 89·8 and 88·4 per cent respectively among those with a BMI below 30 kg/m2 (P = 0·663). The median radiation dose in the whole low- and standard-dose CT groups was 3 and 7 mSv respectively. In the group with BMI below 30 kg/m2, corresponding median doses were 3 and 5 mSv (P < 0·001). Conclusion Low- and standard-dose CT were accurate both in identifying appendicitis and in differentiating between uncomplicated and complicated acute appendicitis. Low-dose CT was associated with a significant radiation dose reduction, suggesting that it should be standard clinical practice at least in patients with a BMI below 30 kg/m2.

Funder

Mary and Georg C. Ehrnrooth Foundation

Sigrid Juselius Foundation

Finnish Academy

Orion Research Foundation

Publisher

Oxford University Press (OUP)

Subject

Surgery

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3