Trainee anaesthetist diagnosis of intraneural injection—a study comparing B-mode ultrasound with the fusion of B-mode and elastography in the soft embalmed Thiel cadaver model
Author:
Publisher
Elsevier BV
Subject
Anesthesiology and Pain Medicine
Link
http://academic.oup.com/bja/article-pdf/117/6/792/8390981/aew337.pdf
Reference28 articles.
1. Ultrasound guidance and peripheral nerve injury: is our vision as sharp as we think it is?;Neal;Reg Anesth Pain Med,2010
2. Incidence of unintentional intraneural injection and postoperative neurological complications with ultrasound-guided interscalene and supraclavicular nerve blocks;Liu;Anaesthesia,2011
3. Incidence and effects of unintentional intraneural injection during ultrasound-guided subgluteal sciatic nerve block;Hara;Reg Anesth Pain Med,2012
4. Acute and nonacute complications associated with interscalene block and shoulder surgery. A prospective study;Borgeat;Anesthesiology,2001
5. Neurological complications after regional anaesthesia: contemporary estimates of risk. Anesth;Brull;Analg,2007
Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Modified thoracoabdominal nerve block through perichondrial approach (M-TAPA): an anatomical study to evaluate the spread of dye after a simulated injection in soft embalmed Thiel cadavers;Regional Anesthesia & Pain Medicine;2023-02-07
2. Elbow valgus stability of the transverse bundle of the ulnar collateral ligament;BMC Musculoskeletal Disorders;2021-10-12
3. Randomized trial comparing the spread of erector spinae block with the combination of erector spinae block and retrolaminar block in soft embalmed Thiel cadavers;Regional Anesthesia & Pain Medicine;2021-09-20
4. Contributions of the Third and Fourth Digits and the Second and Fifth Digits of the Flexor Digitorum Superficialis Muscle to Elbow Valgus Stability;Orthopaedic Journal of Sports Medicine;2021-09-01
5. The feasibility and image quality of using soft embalming cadaver dogs and cats for radiographic and ultrasonographic training;THAI J VET MED;2021