Ultrasound in osteoarthritis of the hand: a comparison to computed tomography and histology

Author:

Husic Rusmir1,Finzel Stephanie2ORCID,Stradner Martin H1,Dreu Manuel3,Hofmeister Alexander4,Beham-Schmid Christine5,Graninger Winfried B1,Fessler Johannes16,Dejaco Christian1ORCID

Affiliation:

1. Division of Rheumatology and Immunology, Medical University of Graz, Graz, Austria

2. Department of Rheumatology and Clinical Immunology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany

3. Department of Anatomy

4. Core Facility Alternative Biomodels & Preclinical Imaging

5. Institute of Pathology

6. Division of Immunology and Pathophysiology, Medical University of Graz, Graz, Austria

Abstract

Abstract Objective To compare structural findings between US, micro-CT (µCT) and histology in people with OA of the hands. Methods We analysed DIP and PIP joints of 31 fingers from 15 dissecting-room cadavers with OA of the hands. The occurrence of bone erosions and osteophytes were recorded by US, µCT and histology at 16 regions for each joint and compared for each method. Results In total, US (n = 558, 56.2% of 992 examined regions) and µCT (n = 493, 49.7%) detected a higher frequency of osteophytes at PIP and DIP joints than histology (n = 161, 23.4% of 689 histological examined regions; P = 0.01). We found a comparable number of erosions with each method [US, n = 52 (5.2%); µCT, n = 43 (4.3%); histology, n = 35 (5.2%)]. Both imaging techniques correlated moderately with each other regarding the detection of osteophytes (r = 0.54, P = 0.002) and erosions (r = 0.43, P = 0.017). Neither US nor µCT correlated with histology regarding erosions or osteophytes. With histology as the reference, US had a sensitivity of 80% and a specificity of 32% to detect osteophytes, whereas µCT had a sensitivity of 73% and a specificity of 27%. For erosions, sensitivities (US 10% and µCT 6%, respectively) were much lower. Microscopically, erosions contained fibrous myxoid tissue extending from subcortical cavities through the breach of cortical bone. Conclusions The ability of US to identify osteophytes was comparable to that of µCT, yielding a good sensitivity when histology was used as the gold standard. The sensitivity of US and µCT to detecting erosions was low compared with histology.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology (medical),Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3