Degree of Safety Against Falls Provided by 4 Different Prosthetic Knee Types in People With Transfemoral Amputation: A Retrospective Observational Study

Author:

Palumbo Pierpaolo1ORCID,Randi Pericle2,Moscato Serena1ORCID,Davalli Angelo3ORCID,Chiari Lorenzo14ORCID

Affiliation:

1. Department of Electrical , Electronic, and Information Engineering “Guglielmo Marconi,” Alma Mater Studiorum University of Bologna, Bologna, Italy

2. Unità operativa di medicina fisica e riabilitazione , INAIL Centro Protesti, Vigoroso di Budrio, Emilia-Romagna, Italy

3. Area ricerca e formazione , INAIL Centro Protesti, Vigoroso di Budrio, Emilia-Romagna, Italy

4. Health Sciences and Technologies , Interdepartmental Center for Industrial Research, Alma Mater Studiorum University of Bologna, Bologna, Italy

Abstract

Abstract Objective People with transfemoral amputation have balance and mobility problems and are at high risk of falling. An adequate prosthetic prescription is essential to maximize their functional levels and enhance their quality of life. This study aimed to evaluate the degree of safety against falls offered by different prosthetic knees. Methods A retrospective study was conducted using data from a center for prosthetic fitting and rehabilitation. Eligible individuals were adults with unilateral transfemoral amputation or knee disarticulation. The prosthetic knee models were grouped into 4 categories: locked knees, articulating mechanical knees (AMKs), fluid-controlled knees (FK), and microprocessor-controlled knees (MPK). The outcome was the number of falls experienced during inpatient rehabilitation while wearing the prosthesis. Association analyses were performed with mixed-effect Poisson models. Propensity score weighting was used to adjust causal estimates for participant confounding factors. Results Data on 1486 hospitalizations of 815 individuals were analyzed. Most hospitalizations (77.4%) were related to individuals with amputation due to trauma. After propensity score weighting, the knee category was significantly associated with falls. People with FK had the highest rate of falling (incidence rate = 2.81 falls per 1000 patient days, 95% CI = 1.96 to 4.02). FK significantly increased the risk of falling compared with MPK (incidence rate ratio [IRRFK-MPK] = 2.44, 95% CI = 1.20 to 4.96). No other comparison among knee categories was significant. Conclusions Fluid-controlled prosthetic knees expose inpatients with transfemoral amputation to higher incidence of falling than MPK during rehabilitation training. Impact These findings can guide clinicians in the selection of safe prostheses and reduction of falls in people with transfemoral amputation during inpatient rehabilitation.

Funder

Istituto Nazionale Assicurazione Infortuni sul Lavoro

Sant’Anna School of Advanced Studies—Pisa

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3