Novel System of Simulation Models for Aneurysm Clipping Training: Description of Models and Assessment of Face, Content, and Construct Validity

Author:

Belykh Evgenii12,Giovani Andrei3,Abramov Irakliy1,Ngo Brandon1,Bardonova Liudmila1,Zhao Xiaochun1,Loymak Thanapong1,Mooney Michael A1,Sheehy John P1,McBryan Sarah1,Tanikawa Rokuya4,Lawton Michael T1,Preul Mark C1

Affiliation:

1. Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA

2. Department of Neurosurgery, New Jersey Medical School, Rutgers University, Newark, New Jersey, USA

3. Department of Neurosurgery, Emergency Clinical Hospital Bagdasar-Arseni, Bucharest, Romania

4. Department of Neurosurgery, Stroke Center Sapporo Teishinkai Hospital, Sapporo, Japan

Abstract

Abstract BACKGROUND Aneurysm clipping simulation models are needed to provide tactile feedback of biological vessels in a nonhazardous but surgically relevant environment. OBJECTIVE To describe a novel system of simulation models for aneurysm clipping training and assess its validity. METHODS Craniotomy models were fabricated to mimic actual tissues and movement restrictions experienced during actual surgery. Turkey wing vessels were used to create aneurysm models with patient-specific geometry. Three simulation models (middle cerebral artery aneurysm clipping via a pterional approach, anterior cerebral artery aneurysm clipping via an interhemispheric approach, and basilar artery aneurysm clipping via an orbitozygomatic pretemporal approach) were subjected to face, content, and construct validity assessments by experienced neurosurgeons (n = 8) and neurosurgery trainees (n = 8). RESULTS Most participants scored the model as replicating actual aneurysm clipping well and scored the difficulty of clipping as being comparable to that of real surgery, confirming face validity. Most participants responded that the model could improve clip-applier-handling skills when working with patients, which confirms content validity. Experienced neurosurgeons performed significantly better than trainees on all 3 models based on subjective (P = .003) and objective (P < .01) ratings and on time to complete the task (P = .04), which confirms construct validity. Simulations were used to discuss clip application strategies and compare them to prototype clinical cases. CONCLUSION This novel aneurysm clipping model can be used safely outside the wet laboratory; it has high face, content, and construct validity; and it can be an effective training tool for microneurosurgery training during aneurysm surgery courses.

Funder

Barrow Neurological Foundation

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3