Automated Measurement of Plasma Cell-Free Hemoglobin Using the Hemolysis Index Check Function

Author:

Barbhuiya Mustafa A1,Pederson Edward C1,Straub Monica L1,Neibauer Terri L1,Salter Wayne F1,Saylor Eric L1,Scott Sofia C1,Zhu Yusheng1

Affiliation:

1. Department of Pathology and Laboratory Medicine, Pennsylvania State University College of Medicine, Hershey, PA

Abstract

Abstract Background The Roche Cobas chemistry analyzer’s hemolysis index (HI) check function can directly report hemoglobin (Hb) concentrations. We aimed to validate the HI check function for the measurement of plasma cell-free Hb. Methods Plasma samples (6 μl) were taken by the analyzer and diluted in normal saline to measure the absorbance for Hb at 570 and 600 nm. Hb concentrations were calculated based on the molar extinction coefficient. Imprecision, lower limit of quantification (LLOQ), and analytical measurement range (AMR) of the assay were evaluated. The accuracy was determined by comparing the results between the new method and an existing spectrophotometric method. We further studied interference of icterus and lipemia and carryover. The performance of the assay in proficiency testing was also evaluated. The reference range was transferred from the existing method. Results Within-run and total CVs were 1.7%–4.2% and 2.1%–7.0%, respectively (n = 20). The LLOQ was 11 mg/dL (CV = 8.1%) with the upper limit of AMR of 506 mg/dL. The results of the new method correlated well with the existing reference assay: Y (new method) = 0.974 x (reference method) + 4.9, r = 0.9990, n = 52. Bilirubin with a concentration up to 60 mg/dL and lipemic index up to 389 did not show significant interference. No significant carryover was detected. The average standard deviation index in proficiency testing was 0.03 ± 0.29. The reference range was <22 mg/dL. Conclusions Plasma cell-free Hb measurement using the HI check function meets the analytical requirements of the plasma cell-free Hb assays. It is simple and cost-effective.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Reference22 articles.

1. Hemolysis and cell-free hemoglobin drive an intrinsic mechanism for human disease;Gladwin;J Clin Invest,2012

2. The clinical sequelae of intravascular hemolysis and extracellular plasma hemoglobin;Rother;JAMA,2005

3. Haemolysis index for the screening of intravascular haemolysis: a novel diagnostic opportunity?;Lippi;Blood Transfus,2018

4. Current methods of haemolysis detection and reporting as a source of risk to patient safety: a narrative review;McCaughey;Clin Biochem Rev,2016

5. Hemolytic anemia;Dhaliwal;Am Fam Physician,2004

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3