Abstract

Abstract Background Rapid identification and quantification of toxic alcohols and ethylene glycol is imperative for appropriate treatment. Clinical laboratories frequently rely on direct injection gas chromatography (GC) methods, but these methods require inlet maintenance and multiple GC systems. To overcome these challenges, we developed a single-column headspace GC method for both toxic alcohols and glycols that streamlines patient sample analysis for toxic alcohol ingestion. Methods Optimal parameters for nonderivatized (volatile) and derivatized (glycol) plasma samples were determined using a 7890 A headspace sampler, an Agilent 7697 A GC system, a DB-200 column, and a flame ionization detector. Limit of Quantification (LoQ), linearity, imprecision, carry-over, method comparison, and interference studies were performed using quality control materials and prepared plasma samples. Results Our volatile method is linear to 3000 mg/L (ethanol) with LoQ concentrations below 20 mg/L (ethanol). The glycol method is linear to 2000 mg/L (ethylene glycol) with LoQ concentrations below 40 mg/L (ethylene glycol). Total assay impression ranged from 1.7% for ethanol to 13.3% for propylene glycol. Both methods were free of sample carryover and compared favorably with a similar clinical method at an outside laboratory. Propionic acid, an accumulating metabolite in methylmalonic acidemia that interferes with ethylene glycol identification by a different method, did not interfere with the ethylene glycol method reported here. Conclusions Our single-column headspace GC method provides reliable, robust, and rapid identification and quantification of commonly encountered toxic alcohols. Clinical laboratories relying on direct injection Gas Chromatography (GC) for toxic alcohol analysis face challenges including frequent inlet maintenance, sample carryover, or the need for separate GC systems for volatile and glycol analysis. We summarize our development and optimization of two headspace GC methods for nonderivatized (volatile) and derivatized (glycol) plasma samples that use a single DB-200 analytical column. These methods are comparable to other GC methods, not prone to sample carryover, eliminate the need for multiple GC systems or columns, and are readily applicable to other laboratories that provide toxic alcohol analysis.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3