Smartphone-based diagnostic for preeclampsia: an mHealth solution for administering the Congo Red Dot (CRD) test in settings with limited resources

Author:

Jonas Stephan Michael12,Deserno Thomas Martin2,Buhimschi Catalin Sorin34,Makin Jennifer5,Choma Michael Andrew167,Buhimschi Irina Alexandra348

Affiliation:

1. Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, CT 06520, USA

2. Department of Medical Informatics, RWTH Aachen University, Aachen, Germany

3. Department of Obstetrics & Gynecology, The Ohio State University College of Medicine, Columbus, OH 43210, USA

4. Center for Perinatal Research, The Research Institute at Nationwide Children’s Hospital, Columbus, OH 43215, USA

5. Department of Obstetrics & Gynecology, University of Pretoria, Kalafong Hospital, South Africa

6. Department of Biomedical Engineering, Yale University School of Engineering and Applied Science, New Haven, CT 06520, USA

7. Department of Pediatrics, Yale University School of Medicine, New Haven, CT 06520, USA

8. Department of Pediatrics, The Ohio State University College of Medicine, Columbus, OH 43215, USA

Abstract

Abstract Objective Morbidity and mortality due to preeclampsia in settings with limited resources often results from delayed diagnosis. The Congo Red Dot (CRD) test, a simple modality to assess the presence of misfolded proteins in urine, shows promise as a diagnostic and prognostic tool for preeclampsia. We propose an innovative mobile health (mHealth) solution that enables the quantification of the CRD test as a batch laboratory test, with minimal cost and equipment. Methods A smartphone application that guides the user through seven easy steps, and that can be used successfully by non-specialized personnel, was developed. After image acquisition, a robust analysis runs on a smartphone, quantifying the CRD test response without the need for an internet connection or additional hardware. In the first stage, the basic image processing algorithms and supporting test standardizations were developed using urine samples from 218 patients. In the second stage, the standardized procedure was evaluated on 328 urine specimens from 273 women. In the third stage, the application was tested for robustness using four different operators and 94 altered samples. Results In the first stage, the image processing chain was set up with high correlation to manual analysis (z-test P < 0.001). In the second stage, a high agreement between manual and automated processing was calculated (Lin’s concordance coefficient ρ c = 0.968). In the last stage, sources of error were identified and remedies were developed accordingly. Altered samples resulted in an acceptable concordance with the manual gold-standard (Lin’s ρc = 0.914). Conclusion Combining smartphone-based image analysis with molecular-specific disease features represents a cost-effective application of mHealth that has the potential to fill gaps in access to health care solutions that are critical to reducing adverse events in resource-poor settings.

Publisher

Oxford University Press (OUP)

Subject

Health Informatics

Reference33 articles.

1. The effectiveness of M-health technologies for improving health and health services: a systematic review protocol;Free;BMC Res Notes.,2010

2. Mapping mHealth research: a decade of evolution;Fiordelli;J Med Internet Res.,2013

3. The smartphone in medicine: a review of current and potential use among physicians and students;Ozdalga;J Med Internet Res.,2012

4. A contact-free respiration monitor for smart bed and ambulatory monitoring applications;Hart;Conf Proc IEEE Eng Med Biol Soc.,2010

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3