Accelerated 2.5-D inversion of airborne transient electromagnetic data using reduced 3-D meshing

Author:

Engebretsen Kim Wann1,Zhang Bo12,Fiandaca Gianluca13ORCID,Madsen Line Meldgaard14ORCID,Auken Esben15,Christiansen Anders Vest14

Affiliation:

1. Department of Geoscience, Aarhus University, C. F. Møllers Alle 4, 8000 Aarhus C, Denmark

2. Institute of Earth Exploration Science and Technology, Jilin University, 130026 Changchun, Jilin, China

3. Department of Earth Sciences, Università degli Studi di Milano, 20122 Milano MI, Italy

4. Aarhus University Centre for Water Technology (WATEC), Aarhus University, 8000 Aarhus C, Denmark

5. Geological Survey of Denmark and Greenland, 1350 Copenhagen, Denmark

Abstract

SUMMARY Airborne systems collecting transient electromagnetic data are able to gather large amounts of data over large areas in a very short time. These data are most often interpreted through 1-D inversions, due to the availability of robust, fast and efficient codes. However, in areas where the subsurface contains complex structures or large conductivity contrasts, 1-D inversions may introduce artefacts into the models, which may prevent correct interpretation of the results. In these cases, 2-D or 3-D inversion should be used. Here, we present a 2.5-D inversion code using 3-D forward modelling combined with a 2-D model grid. A 2.5-D inversion is useful where the flight lines are spaced far apart, in which case a 3-D inversion would not add value in relation to the added computational cost and complexity. By exploiting the symmetry of the transmitter and receiver system we are able to perform forward calculations on a reduced 3-D mesh using only half the domain transecting the centre of the transmitter and receiver system. The forward responses and sensitivities from the reduced 3-D mesh are projected onto a structured 2-D model grid following the flight direction. The difference in forward calculations is within 1.4 per cent using the reduced mesh compared to a full 3-D solution. The inversion code is tested on a synthetic example constructed with complex geology and high conductivity contrasts and the results are compared to a 1-D inversion. We find that the 2.5-D inversion recovers both the conductivity values and shape of the true model with a significantly higher accuracy than the 1-D inversion. Finally, the results are supported by a field case using airborne TEM data from the island of Mayotte. The inverted flight line consisted of 418 soundings, and the inversion spent an average of 6750 s per iteration, converging in 16 iterations with a peak memory usage of 97 GB, using 18 logical processors. In general, the total time of the 2-D inversions compared to a full 3-D inversion is reduced by a factor of 2.5 while the memory consumption was reduced by a factor of 2, reflecting the half-mesh approach.

Funder

Horizon 2020

Villum Fonden

Aarhus University Centre for Water Technology

Publisher

Oxford University Press (OUP)

Subject

Geochemistry and Petrology,Geophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3