PATIENT DOSE IN DIGITAL RADIOGRAPHY UTILISING BMI CLASSIFICATION

Author:

Metaxas Vasileios I1,Messaris Gerasimos A1,Lekatou Aristea N1,Petsas Theodore G2,Panayiotakis George S1

Affiliation:

1. Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece

2. Department of Radiology, School of Medicine, University of Patras, Patras, Greece

Abstract

Abstract Dose audit is important towards optimisation of patients’ radiation protection in diagnostic radiography. In this study, the effect of the body mass index (BMI) on radiation dose received by 1869 adult patients undergoing chest, abdomen, lumbar spine, kidneys and urinary bladder (KUB) and pelvis radiography in an X-ray room with a digital radiography system was investigated. Patients were categorised into three groups (normal, overweight and obese) based on the BMI values. The patients’ entrance surface air kerma (ESAK) and the effective dose (ED) were calculated based on the X-ray tube output, exposure parameters and technical data, as well as utilising appropriate conversion coefficients of the recorded kerma area product (KAP) values. The local diagnostic reference levels (LDRLs) were established at the 75th percentile of the distribution of ESAK and KAP values. Statistically, a significant increase was found in ESAK, KAP and ED values, for all examinations, both for overweight and obese patients compared to normal patients (Mann–Whitney test, p < 0.0001). Regarding the gender of the patients, a statistically significant increase was found in the dose values for male patients compared to female patients, except for the chest LAT examinations (Mann–Whitney test, p = 0.06). The percentage increase for chest PA, chest LAT, abdomen AP, lumbar spine AP, lumbar spine LAT, pelvis AP and KUB AP in overweight patients was 75%, 100%, 136%, 130%, 70%, 66% and 174% for median ESAK, 67%, 81%, 135%, 134%, 85%, 63% and 172% for median KAP, as well as 89%, 54%, 146%, 138%, 82%, 57% and 183% for median ED values, respectively. For obese patients, the corresponding increases were 200%, 186%, 459%, 345%, 203%, 150% and 785% for median ESAK, 200%, 185%, 423%, 357%, 227%, 142% and 597% for median KAP, as well as 222%, 156%, 446%, 363%, 218%, 136% and 625% for median ED. The corresponding LDRLs for overweight patients were 0.17 mGy, 1.21 mGy, 3.74 mGy, 7.70 mGy, 7.99 mGy, 4.07mGy, 5.03 mGy and 0.13 Gy cm2, 0.69 Gy cm2, 2.35 Gy cm2, 2.10 Gy cm2, 2.59 Gy cm2, 2.13 Gy cm2, 2.49 Gy cm2 in terms of ESAK and KAP values, respectively, while in the case of obese patients were 0.28 mGy, 1.82 mGy, 7.26 mGy, 15.10 mGy, 13.86 mGy, 6.89 mGy, 13.40 mGy and 0.21 Gy cm2, 1.10 Gy cm2, 4.68 Gy cm2, 4.01 Gy cm2, 4.80 Gy cm2, 3.27 Gy cm2, 6.02 Gy cm2, respectively. It can be concluded that overweight and obese patients received a significantly increased radiation dose. Careful adjustment of imaging protocols is needed for these patients to reduce patient dose, while keeping the image quality at an acceptable level. Additional studies need to be conducted for these patient groups, that could further contribute to the development of radiation protection culture in diagnostic radiography.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference43 articles.

1. Council Directive 2013/59/Euratom of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionizing radiation, and repealing directives 89/618/ Euratom, 90/641/Euratom, 96/29/Euratom, 97/43/Euratom and 2003/122/Euratom;Off. J. Eur. Commun.,2014

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3