Evaluation of the 2021 European Society of Cardiology guidelines in pre-existing right bundle branch block patients undergoing transcatheter aortic valve implantation with a balloon-expandable valve

Author:

Isogai Toshiaki1ORCID,Dykun Iryna12,Agrawal Ankit1,Shekhar Shashank1,Tarakji Khaldoun G1,Wazni Oussama M1,Kalra Ankur1,Krishnaswamy Amar1,Reed Grant W1,Kapadia Samir R1,Puri Rishi1

Affiliation:

1. Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic , 9500 Euclid Avenue, J2-3 , Cleveland, OH 44195, USA

2. Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University of Duisburg-Essen , Essen, Germany

Abstract

Abstract Aims The 2021 European Society of Cardiology guidelines recommend early pacemaker implantation in pre-existing right bundle branch block (RBBB) patients who develop PR prolongation or QRS axis change after transcatheter aortic valve implantation (TAVI). We aimed to evaluate this recommendation in TAVI recipients with a balloon-expandable valve (BEV). Methods and results We retrospectively reviewed 188 pre-existing RBBB patients without pre-existing permanent pacemaker (PPM) who underwent TAVI with a BEV at our institution in 2015–19. Patients who developed high-degree atrioventricular block (HAVB) during TAVI or within 24 h post-TAVI were excluded. Eligible patients were divided according to the guideline-directed criteria (ΔPR interval ≥20 ms and/or QRS axis change). Patients who met the criteria (n = 102, 54.3%), compared with those who did not (n = 86), had a higher prevalence of baseline right axis deviation and were more likely to have received a larger valve with greater oversizing. The 30-day delayed HAVB rate did not differ significantly between the groups (3.9% vs. 4.7%, P = 1.00; odds ratio = 0.84, 95% confidence interval = 0.20–3.45). There was also no significant difference in terms of death (5.0% vs. 8.4% at 1 year; overall log-rank P = 0.94) or a composite of death or PPM implantation (14.8% vs. 16.6% at 1 year; overall log-rank P = 0.94) during follow-up post-TAVI. The majority of PR prolongations (79.4%) and QRS axis changes (52.0%) regressed within the following 24 h. Conclusion The present data did not demonstrate an association of significant changes in PR interval or QRS axis with heightened delayed HAVB risk in BEV recipients with pre-existing RBBB. Prospective studies are warranted to confirm these findings.

Funder

Jennifer and Robert McNeil

German Research Foundation

Publisher

Oxford University Press (OUP)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3