Task-specific uncertainty estimation for medical CT measurements
-
Published:2018-12-20
Issue:2
Volume:7
Page:627-635
-
ISSN:2194-878X
-
Container-title:Journal of Sensors and Sensor Systems
-
language:en
-
Short-container-title:J. Sens. Sens. Syst.
Author:
Bredemann Judith,Schmitt Robert H.
Abstract
Abstract. Computed tomography (CT) is an important imaging technology for medical
diagnosis purposes. However, by improving the CT scanners with regard to scan
resolution and times, the use of CT is no longer limited to the diagnostic
field. Different minimally invasive procedures are image-guided.
CT-based surgical navigation utilizes 3-D measurements. Therefore,
uncertainties in the imaging and image processing lead to erroneous initial
conditions for the navigation process and result in a higher risk of
unintended injuries of anatomical risk structures. To minimize the risk of
unintended injuries, the uncertainties of the imaging process need to be
estimated and considered during the planning of minimally invasive surgery.
The estimation of uncertainties for medical measurements is still at the
beginning though. Within this contribution, we show that it is important to
consider the uncertainty of different measurement tasks during surgical
planning using the example of minimally invasive surgery to the lateral skull
base. A method for the task-specific uncertainty estimation is used to
estimate the uncertainties for defined measurement tasks. Afterwards, we will
discuss how the results have to be considered during the surgical planning
process.
Funder
Deutsche Forschungsgemeinschaft
Publisher
Copernicus GmbH
Subject
Electrical and Electronic Engineering,Instrumentation
Reference32 articles.
1. Bartscher, M., Hilpert, U., Goebbels, J., and Weidemann, G.: Enhancement and Proof of Accuracy of Industrial Computed Tomography (CT) Measurements, CIRP Annals, 56, 495–498, https://doi.org/10.1016/j.cirp.2007.05.118, 2007. 2. Bartscher, M., Hilpert, U., and Fiedler, D.: Determination of the measurement uncertainty of computed tomography measurements using a cylinder head as an example, Tech. Mess., 75, 178–186, 2008. 3. Bell, B., Gerber, N., Williamson, T., Gavaghan, K., Wimmer, W., Caversaccio, M., and Weber, S.: In vitro accuracy evaluation of image-guided robot system for direct cochlear access, in: Otology & neurotology: official publication of the American Otological Society, American Neurotology Society and European Academy of Otology and Neurotology, 34, 1284–1290, https://doi.org/10.1097/MAO.0b013e31829561b6, 2013. 4. Bredemann, J., Voigtmann, C., Schmitt, R., Stenin, I., Kristin, J., Klenzner, T., and Schipper, J.: Determining the patient's risk in minimally invasive surgery to the lateral skull base, in: 15. CURAC Annual Conference – Tagungsband der Jahrestagung der Deutschen Gesellschaft für computer- und roboterassistierte Chirurgie e.V., 29 September–1 October 2016, Bern/Swiss, 155–161, 2016. 5. Bredemann, J., Voigtmann, C., Jantzen, M., and Schmitt, R. H.: Bohrkopfintegrierte Sensorik zur Absicherung medizinischer Bohrprozesse, Tagungsband der 16. Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassisstierte Chirurgie, Hannover, 2017.
Cited by
3 articles.
订阅此论文施引文献