Laser frequency stabilization based on a universal sub-Doppler NICE-OHMS instrumentation for the potential application in atmospheric lidar
-
Published:2019-03-19
Issue:3
Volume:12
Page:1807-1814
-
ISSN:1867-8548
-
Container-title:Atmospheric Measurement Techniques
-
language:en
-
Short-container-title:Atmos. Meas. Tech.
Author:
Zhou Yueting, Liu Jianxin, Guo Songjie, Zhao Gang, Ma WeiguangORCID, Cao Zhensong, Dong Lei, Zhang Lei, Yin Wangbao, Wu Yongqian, Xiao Lianxuan, Axner OveORCID, Jia Suotang
Abstract
Abstract. Lidar is an effective tool for high-altitude atmospheric measurement in which
a weak absorption line for the target gas is selected to ensure a large
optical depth. The laser frequency stabilization to the line center is
required, and a sub-Doppler (sD) spectroscopy of the target line is preferred
as a frequency reference. In this paper, a novel universal sD noise-immune cavity-enhanced optical heterodyne molecular
spectroscopy
(NICE-OHMS)
instrumentation based on a fiber-coupled optical single-sideband
electro-optic modulator (f-SSM) for the potential application in atmospheric
lidar for different target gases with different types of lasers is reported.
The f-SSM can replace all frequency actuators in the system, so as to
eliminate the individual design of feedback servos that often are tailored
for each laser. The universality of the instrumentation was demonstrated by
the alternative use of either an Er-doped fiber laser or a whispering-gallery-mode laser. Then the instruments based on both lasers were used to produce
the sD signals of acetylene, which worked as a frequency reference to
stabilize the laser. By performing the lockings, relative frequency
stabilizations of 8.3×10-13 and 7.5×10-13 at
an integration time of 240 s were demonstrated.
Publisher
Copernicus GmbH
Subject
Atmospheric Science
Reference42 articles.
1. Axner, O., Ma, W., and Foltynowicz, A.: Sub-Doppler dispersion and
noise-immune cavity-enhanced optical heterodyne molecular spectroscopy
revised, J. Opt. Soc. Am. B, 25,
1166–1177, 2008. 2. Axner, O., Ehlers, P., Foltynowicz, A., Silander, I., and Wang, J.: NICE-OHMS
– Frequency Modulation Cavity-Enhanced Spectroscopy – Principles and
Performance, in: Cavity-Enhanced Spectroscopy and Sensing, edited by: Loock, H. P. and
Gagliardi, G., Springer Series in Optical Sciences, Springer Verlag,
Berlin, 2014. 3. Bell, C. L., Hancock, G., Peverall, R., Ritchie, G. A. D., van Helden, J. H.,
and van Leeuwen, N. J.: Characterization of an external cavity diode laser
based ring cavity NICE-OHMS system, Opt. Express, 17, 9834–9839, 2009. 4. Chen, T. L. and Liu, Y. W.: Noise-immune cavity-enhanced optical heterodyne
molecular spectrometry on N2O 1.283 µm transition based on a
quantum-dot external-cavity diode laser, Opt. Lett., 40, 4352–4355, 2015. 5. Chen, T. L. and Liu, Y. W.: Sub-Doppler resolution near-infrared spectroscopy
at 1.28 µm with the noise-immune cavity-enhanced optical heterodyne
molecular spectroscopy method, Opt. Lett., 42, 2447–2450, 2017.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|