SIMULATION AND ANALYSIS OF PHOTOGRAMMETRIC UAV IMAGE BLOCKS: INFLUENCE OF CAMERA CALIBRATION ERROR

Author:

Zhou Y.,Rupnik E.,Meynard C.,Thom C.,Pierrot-Deseilligny M.

Abstract

Abstract. Unmanned aerial vehicles (UAV) are increasingly used for topographic mapping. The camera calibration for UAV image blocks can be performed a priori or during the bundle block adjustment (self-calibration). For an area of interest with flat, corridor configuration, the focal length of camera is highly correlated with the height of camera. Furthermore, systematic errors of camera calibration accumulate on the longer dimension and cause deformation. Therefore, special precautions must be taken when estimating camera calibration parameters. In this paper, a simulated, error-free aerial image block is generated. error is then added on camera calibration and given as initial solution to bundle block adjustment. Depending on the nature of the error and the investigation purpose, camera calibration parameters are either fixed or re-estimated during the bundle block adjustment. The objective is to investigate how certain errors in the camera calibration impact the accuracy of 3D measurement without the influence of other errors. All experiments are carried out with Fraser camera calibration model being employed. When adopting a proper flight configuration, an error on focal length for the initial camera calibration can be corrected almost entirely during bundle block adjustment. For the case where an erroneous focal length is given for pre-calibration and not re-estimated, the presence of oblique images limits the drift on camera height hence gives better camera pose estimation. Other than that, the error on focal length when neglecting its variation during the acquisition (e.g., due to camera temperature increase) is also investigated; a bowl effect is observed when one focal length is given in camera pre-calibration to the whole image block. At last, a local error is added in image space to simulate camera flaws; this type of error is more difficult to be corrected with the Fraser camera model and the accuracy of 3D measurement degrades substantially.

Publisher

Copernicus GmbH

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3