Performance analysis of the NanoScan SMPS and the Mini WRAS Ultrafine Aerosol Particle Size Spectrometers

Author:

Ahlawat Ajit,Weinhold Kay,Marval Jesus,Tronville PaoloORCID,Leskinen Ari,Komppula Mika,Gerwig HolgerORCID,Gerling Lars,Weber Stephan,Jørgensen Rikke BrammingORCID,Jensen Thomas NørregaardORCID,Merizak MarouaneORCID,Vogt Ulrich,Ribalta Carla,Viana MarORCID,Schmitz Andre,Chiesa Maria,Gerosa GiacomoORCID,Keck Lothar,Pesch Markus,Steiner GerhardORCID,Krinke Thomas,Tritscher TorstenORCID,Birmili Wolfram,Wiedensohler AlfredORCID

Abstract

Abstract. In aerosol science, there is an increasing interest to perform mobile measurements to obtain number size distribution of ultrafine particles (UFP), using portable instruments based on unipolar charging and size segregation by electrical particle mobility. Applications of such measurements range from ambient and indoor aerosol studies to source identification in work environments. However, knowledge on the actual measurement uncertainties of these portable instruments under various conditions has been limited. This investigation presents results from an intercomparison workshop conducted at the World Calibration Center for Aerosol Physics (WCCAP) in Leipzig, Germany, in January 2020. Manufacturers and users were invited to have their portable instruments tested and compared against reference instrumentation for particle number size distributions (PNSD) and total particle number concentration (PNC). In particular, the performances and uncertainties of the NanoScan SMPS (Scanning Mobility Particle Sizer) Model 3910 (TSI Inc.) and the Mini Wide Range Aerosol Spectrometer (WRAS) Model 1371 (Grimm Aerosol Technik) were investigated extensively against the WCCAP Mobility Particle Size Spectrometers (MPSS) and Condensation Particle Counters (CPC). A total of 11 TSI NanoScan SMPS and 4 GRIMM Mini WRAS instruments were characterized for ambient aerosols as well as lab-generated aerosols. The workshop results affirm that the portable instruments must be serviced and calibrated annually or prior field studies to provide measurements within the given uncertainties. It should be noted that users should carry out timely service, maintenance and calibration of portable instruments at their facilities. During initial inspection, non-serviced NanoScan SMPS instruments overestimated a dominant ultrafine aerosol mode by 120 % at around 80 nm. Maintenance and servicing improved the performance. Overall, the performance of NanoScan SMPS instruments improved for the ultrafine aerosol mode while the PNC in the fine aerosol mode still overestimated by up to 80 %. The latter effect seems to be systematically related to the unipolar charging of particles, and the reduced sensitivity of electrical particle mobility with increasing particle size above 200 nm. Due to shift in the second mode of bimodal distribution, particles are overcounted around 100 nm. With regard to the integral PNC, some of the NanoScan SMPS found to be in good agreement (i.e. within 20 %) compared to the reference CPC. In addition, a reasonably good unit-to-unit agreement within ±20 % was found for NanoScan SMPS instruments. The Mini WRAS instruments, after proper cleaning and servicing, provided improved results within ±15 % deviation in PNC in the ultrafine aerosol mode. Overall, most of the GRIMM Mini WRAS instruments (operating with software version 10.0) agrees well with PNC (i.e. 10–50 %) when the ultrafine mode was dominant. Conversely, PNC of the fine aerosol mode was systematically underestimated by 60 % above 100 nm. Except for one instrument, the integral PNC of the GRIMM Mini WRAS spectrometers were within an uncertainty range of ±20 % compared to the reference CPC. Additionally, it is important for users to note that the Mini WRAS performed significantly better when using software version 10.0 compared to version 8.2. The workshop results suggest that despite the above-mentioned uncertainties, these portable instruments are suited for mobile ultrafine particle measurements to detect relative differences in the PNSD such as source apportionment studies of ultrafine particles at work places or outdoors near sources.

Funder

Umweltbundesamt

Publisher

Copernicus GmbH

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3