The airborne mass spectrometer AIMS – Part 1: AIMS-H<sub>2</sub>O for UTLS water vapor measurements

Author:

Kaufmann S.ORCID,Voigt C.ORCID,Jurkat T.,Thornberry T.ORCID,Fahey D. W.ORCID,Gao R.-S.,Schlage R.,Schäuble D.,Zöger M.

Abstract

Abstract. In the upper troposphere and lower stratosphere (UTLS), the accurate quantification of low water vapor concentrations has presented a significant measurement challenge. The instrumental uncertainties are passed on to estimates of H2O transport, cloud formation and the H2O role in the UTLS energy budget and resulting effects on surface temperatures. To address the uncertainty in UTLS H2O determination, the airborne mass spectrometer AIMS-H2O, with in-flight calibration, has been developed for fast and accurate airborne water vapor measurements. We present the new setup to measure water vapor by direct ionization of ambient air. Air is sampled via a backward facing inlet that includes a bypass flow to assure short residence times (< 0.2 s) in the inlet line, which allows the instrument to achieve a time resolution of ∼ 4 Hz. From the main inlet flow, a smaller flow is extracted into the novel pressure-controlled gas discharge ion source of the mass spectrometer. The air is directed through the gas discharge region where water molecules react to form hydronium ion clusters, H3O+(H2O)n (n= 0, 1, 2), in a complex reaction scheme similar to the reactions in the D-region of the ionosphere. These ions are counted to quantify the ambient water vapor mixing ratio. The instrument is calibrated during flight using a new calibration source based on the catalytic reaction of H2 and O2 on a Pt surface to generate a calibration standard with well defined and stable H2O mixing ratios. In order to increase data quality over a range of mixing ratios, two data evaluation methods are presented for lower and higher H2O mixing ratios respectively, using either only the H3O+(H2O) ions or the ratio of all water vapor dependent ions to the total ion current. Altogether, a range of water vapor mixing ratios from 1 to 500 ppmv (mole ratio, 10−6 mol mol−1) can be covered with an accuracy between 7 and 15 %. AIMS-H2O was deployed on two DLR research aircraft, the Falcon during CONCERT (Contrail and Cirrus Experiment) in 2011, and HALO during ML-CIRRUS (Mid-Latitude Cirrus) in 2014. The comparison of AIMS-H2O with the SHARC tunable diode laser hygrometer during ML-CIRRUS shows a very good overall agreement between both instruments for the entire campaign.

Funder

Deutsche Forschungsgemeinschaft

Helmholtz-Gemeinschaft

Publisher

Copernicus GmbH

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3