Aerosol trace element solubility determined using ultrapure water batch leaching: an intercomparison study of four different leaching protocols
-
Published:2024-05-24
Issue:10
Volume:17
Page:3147-3156
-
ISSN:1867-8548
-
Container-title:Atmospheric Measurement Techniques
-
language:en
-
Short-container-title:Atmos. Meas. Tech.
Author:
Li Rui, Panda Prema Piyusha, Chen Yizhu, Zhu Zhenming, Wang Fu, Zhu Yujiao, Meng He, Ren Yan, Kumar Ashwini, Tang MingjinORCID
Abstract
Abstract. Solubility of aerosol trace elements, which determines their bioavailability and reactivity, is operationally defined and strongly depends on the leaching protocol used. Ultrapure water batch leaching is one of the most widely used leaching protocols, while the specific leaching protocols used in different labs can still differ in agitation methods, contact time, and filter pore size. It is yet unclear to which extent the difference in these experimental parameters would affect the aerosol trace element solubility reported. This work examined the effects of agitation methods, filter pore size, and contact time on the solubility of nine aerosol trace elements and found that the difference in agitation methods (shaking vs. sonication), filter pore size (0.22 vs. 0.45 µm), and contact time (1 vs. 2 h) only led to small and sometimes insignificant difference in the reported solubility. We further compared aerosol trace element solubility determined using four ultrapure water leaching protocols, which are adopted by four different labs and vary in agitation methods, filter pore size, and/or contact time, and observed good agreement in the reported solubility. Therefore, our work suggests that although ultrapure water batch leaching protocols used by different labs vary in specific experimental parameters, the determined aerosol trace element solubility is comparable. We recommend that ultrapure water batch leaching be one of the reference leaching schemes and emphasize that additional consensus in the community on agitation methods, contact time, and filter pore size is needed to formulate a standard operating procedure for ultrapure water batch leaching.
Funder
National Natural Science Foundation of China Guangzhou Municipal Science and Technology Bureau Basic and Applied Basic Research Foundation of Guangdong Province
Publisher
Copernicus GmbH
Reference48 articles.
1. Al-Abadleh, H. A.: Iron content in aerosol particles and its impact on atmospheric chemistry, Chem. Commun., 60, 1840–1855, 2024. 2. Alexander, B., Park, R. J., Jacob, D. J., and Gong, S.: Transition metal-catalyzed oxidation of atmospheric sulfur: Global implications for the sulfur budget, J. Geophys. Res.-Atmos., 114, D02309, https://doi.org/10.1029/2008JD010486, 2009. 3. Baker, A. R. and Croot, P. L.: Atmospheric and marine controls on aerosol iron solubility in seawater, Mar. Chem., 120, 4–13, 2010. 4. Baker, A. R. and Jickells, T. D.: Mineral particle size as a control on aerosol iron solubility, Geophys. Res. Lett., 33, L17608, https://doi.org/10.1029/2006GL026557, 2006. 5. Baker, A. R., Kelly, S. D., Biswas, K. F., Witt, M., and Jickells, T. D.: Atmospheric deposition of nutrients to the Atlantic Ocean, Geophys. Res. Lett., 30, 2296, https://doi.org/10.1029/2003GL018518, 2003.
|
|