Linearization of the effect of slit function changes for improving Ozone Monitoring Instrument ozone profile retrievals
-
Published:2019-07-11
Issue:7
Volume:12
Page:3777-3788
-
ISSN:1867-8548
-
Container-title:Atmospheric Measurement Techniques
-
language:en
-
Short-container-title:Atmos. Meas. Tech.
Author:
Bak JuseonORCID, Liu Xiong, Sun KangORCID, Chance KellyORCID, Kim Jae-Hwan
Abstract
Abstract. We introduce a method that accounts for errors caused by the slit function
in an optimal-estimation-based spectral fitting process to improve ozone
profile retrievals from the Ozone Monitoring Instrument (OMI) ultraviolet
measurements (270–330 nm). Previously, a slit function was parameterized as
a standard Gaussian by fitting the full width at half maximum (FWHM) of the
slit function from climatological OMI solar irradiances. This cannot account
for the temporal variation in slit function in irradiance, the intra-orbit
changes due to thermally induced change and scene inhomogeneity, and
potential differences in the slit functions of irradiance and radiance
measurements. As a result, radiance simulation errors may be induced due to
convolving reference spectra with incorrect slit functions. To better
represent the shape of the slit functions, we implement a more generic super
Gaussian slit function with two free parameters (slit width and shape
factor); it becomes standard Gaussian when the shape factor is fixed to be 2. The effects of errors in slit function parameters on radiance spectra,
referred to as pseudo absorbers (PAs), are linearized by convolving
high-resolution cross sections or simulated radiances with the partial
derivatives of the slit function with respect to the slit parameters. The
PAs are included in the spectral fitting scaled by fitting coefficients that
are iteratively adjusted as elements of the state vector along with ozone
and other fitting parameters. The fitting coefficients vary with cross-track
and along-track pixels and show sensitivity to heterogeneous scenes. The PA
spectrum is quite similar in the Hartley band below 310 nm for both standard
and super Gaussians, but is more distinctly structured in the Huggins band
above 310 nm with the use of super Gaussian slit functions. Finally, we
demonstrate that some spikes of fitting residuals are slightly smoothed by
accounting for the slit function errors. Comparisons with ozonesondes
demonstrate noticeable improvements when using PAs for both standard and
super Gaussians, especially for reducing the systematic biases in the
tropics and midlatitudes (mean biases of tropospheric column ozone reduced
from -1.4∼0.7 to 0.0∼0.4 DU) and reducing
the standard deviations of tropospheric ozone column differences at
high latitudes (by 1 DU for the super Gaussian). Including PAs also makes
the retrievals consistent between standard and super Gaussians. This study
corroborates the slit function differences between radiance and irradiance,
demonstrating that it is important to account for such differences in the
ozone profile retrievals.
Publisher
Copernicus GmbH
Subject
Atmospheric Science
Reference30 articles.
1. Azam, F. and Richter, A.: GOME2 on MetOp: Follow on analysis of GOME2 in
orbit degradation, Final report, EUM/CO/09/4600000696/RM, available
at: https://www.eumetsat.int/website/wcm/idc/idcplg?IdcService=GET_FILE&dDocName=PDF_GOME_DEG_REP&RevisionSelectionMethod=LatestReleased&Rendition=Web (last access: 7 September 2016), 2015. 2. Bak, J., Liu, X., Wei, J. C., Pan, L. L., Chance, K., and Kim, J. H.:
Improvement of OMI ozone profile retrievals in the upper troposphere and
lower stratosphere by the use of a tropopause-based ozone profile
climatology, Atmos. Meas. Tech., 6, 2239–2254, https://doi.org/10.5194/amt-6-2239-2013,
2013. 3. Bak, J., Liu, X., Kim, J.-H., Haffner, D. P., Chance, K., Yang, K., and Sun,
K.: Characterization and correction of OMPS nadir mapper measurements for
ozone profile retrievals, Atmos. Meas. Tech., 10, 4373–4388,
https://doi.org/10.5194/amt-10-4373-2017, 2017. 4. Beirle, S., Sihler, H., and Wagner, T.: Linearisation of the effects of
spectral shift and stretch in DOAS analysis, Atmos. Meas. Tech., 6,
661–675, https://doi.org/10.5194/amt-6-661-2013, 2013. 5. Beirle, S., Lampel, J., Lerot, C., Sihler, H., and Wagner, T.:
Parameterizing the instrumental spectral response function and its changes
by a super-Gaussian and its derivatives, Atmos. Meas. Tech., 10, 581–598,
https://doi.org/10.5194/amt-10-581-2017, 2017.
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|