Characterisation of a self-sustained, water-based condensation particle counter for aircraft cruising pressure level operation
-
Published:2023-07-21
Issue:14
Volume:16
Page:3505-3514
-
ISSN:1867-8548
-
Container-title:Atmospheric Measurement Techniques
-
language:en
-
Short-container-title:Atmos. Meas. Tech.
Author:
Weber PatrickORCID, Bischof Oliver F., Fischer Benedikt, Berg Marcel, Hering SusanneORCID, Spielman Steven, Lewis Gregory, Petzold AndreasORCID, Bundke UlrichORCID
Abstract
Abstract. Aerosol particle number concentration measurements are a
crucial part of aerosol research. Vertical profile measurements and
high-altitude/low-pressure performance of the respective instruments become
more important for remote sensing validation and a vital tool for the
observation of climate variables. This study tests the new, commercially
available water condensation particle counter (MAGIC 210-LP) for the
deployment at aircraft cruising pressure levels that the European research
infrastructure IAGOS (In-service Aircraft for a Global Observing System;
http://www.iagos.org, last access: 2 May 2023) is aiming for by operating measurement instrumentation onboard passenger aircraft. We conducted laboratory experiments for conditions
to simulate passenger aircraft flight altitude at operation pressure. We
demonstrate that this type of water condensation particle counter shows
excellent agreement with a butanol-based instrument used in parallel. A
Faraday cup aerosol electrometer serves as the reference instrument.
Experiments are performed with test aerosol ammonium sulfate and fresh
combustion soot at pressure levels ranging from 700 to 200 hPa. For soluble particles like ammonium sulfate, the 50 % detection efficiency cut-off diameter (D50) is around 5 nm and does not differ significantly for all
performed experiments. For non-soluble fresh soot particles, the D50
cut-off diameter of approximately 10 nm does not vary substantially as a
function of pressure, whereas the 90 % detection efficiency cut-off
diameter D90 increases from 19 nm at 700 hPa to 37 nm at 200 hPa. The overall counting efficiency for particles larger than 40 nm reaches 100 % for working pressures of 200 hPa and higher.
Funder
Bundesministerium für Bildung und Forschung Forschungszentrum Jülich
Publisher
Copernicus GmbH
Subject
Atmospheric Science
Reference34 articles.
1. Aitken, J.: On the Number of Dust Particles in the Atmosphere, Nature, 37, 428–430, https://doi.org/10.1038/037428a0, 1888. 2. Banse, D. F., Esfeld, K., Hermann, M., Sierau, B., and Wiedensohler, A.:
Particle counting efficiency of the TSI CPC 3762 for different operating
parameters, J. Aerosol Sci., 32, 157–161,
https://doi.org/10.1016/S0021-8502(00)00060-4, 2001. 3. Bischof, O., Weber, P., Bundke, U., Petzold, A., and Kiendler-Scharr, A.:
Characterization of the Miniaturized Inverted Flame Burner as a Combustion
Source to Generate a Nanoparticle Calibration Aerosol, Aerosol, Emiss.
Control Sci. Technol., 6, 37–46, https://doi.org/10.1007/s40825-019-00147-w, 2020. 4. Bischof, O. F.: Application-Specific Calibration of Condensation Particle
Counters under Low Pressure Conditions, Dissertation, Verlag des
Forschungszentrums Jülich, Energie Umwelt, Band 576, ISBN 978-3-95806-629-8, 2022. 5. Bojinski, S., Verstraete, M., Peterson, T. C., Richter, C., Simmons, A., and
Zemp, M.: The Concept of Essential Climate Variables in Support of Climate
Research, Applications, and Policy, B. Am. Meteorol. Soc., 95, 1431–1443, https://doi.org/10.1175/BAMS-D-13-00047.1, 2014.
|
|