Comparison of parallel or convergent proximal schanz screw placement of pertrochanteric fixator in intertrochanteric fracture model
-
Published:2017-08-15
Issue:2
Volume:8
Page:259-266
-
ISSN:2191-916X
-
Container-title:Mechanical Sciences
-
language:en
-
Short-container-title:Mech. Sci.
Author:
Gok Arif,Inal Sermet,Taspinar Ferruh,Gulbandilar Eyyup,Gok Kadir
Abstract
Abstract. Intertrochanteric femoral fractures are serious traumas among elderly patients. In these patients, external fixator is a preferable method for the fixation of fractures. Therefore, this study was planned to compare the parallel and convergent proximal schanz screw placement of pertrochanteric fixator in the intertrochanteric femoral fractures with respect to biomechanical forces that stabilize the fracture line and to present their clinical importance. A commercial finite element based program, AnsysWorkbench was used to investigate the biomechanical parameters of the femoral intertrochanteric fractures and different placement of implants. The von Mises stress, von Mises strain and shear stress on the proximal and distal surface of the fracture line were lower in the convergent pertrochanteric fixator. Proximal schanz screws in convergent configuration pertrochanteric fixator had greater stress and strain values than proximal schanz screws in parallel configuration pertrochanteric fixator. The distance between the proximal schanz screws on the fracture line was measured as 12 mm in convergent configuration pertrochanteric fixator, and as 3.5 mm in parallel configuration pertrochanteric fixator. The angle between the proximal schanz screws in the convergent configuration was measured as 12.88°. The effect of convergent and parallel configuration pertrochanteric fixators on axial loading demonstrated that convergent configuration pertrochanteric fixator was safer in this respect.
Publisher
Copernicus GmbH
Subject
Industrial and Manufacturing Engineering,Fluid Flow and Transfer Processes,Mechanical Engineering,Mechanics of Materials,Civil and Structural Engineering,Control and Systems Engineering
Reference29 articles.
1. Aly, T. A., Hafez, K., El-nor, T. A., and, Osama, A.: Treatment of Trochanteric Fractures By External Fixator in Patients With High Unacceptable Operative Risk, Pan Arab. J. Orth. Trauma, 8, 157–162, 2004. 2. Audigé, L., Hanson, B., and Swiontkowski, M. F.: Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices, Int. Orthop., 27, 197–203, 2003. 3. Badras, L., Skretas, E., and Ed, V.: Traitement des fractures pertrochantériennes par fixateurexterne, Rev. Chir. Orthop., 84, 461–465, 1997. 4. Barros, J. W., Ferreira, C. D., Freitas, A. A., and Farah, S.: External fixation of intertrochanteric fractures of the femur, Int. Orthop., 19, 217–219, 1995. 5. Bong, M. R., Patel, V., Iesaka, K., Egol, K. A., Kummer, F. J., and Koval, K. J.: Comparison of a Sliding Hip Screw with a Trochanteric Lateral Support Plate to an Intramedullary Hip Screw for Fixation of Unstable Intertrochanteric Hip Fractures: A Cadaver Study, J. Trauma Acute Care Surg., 56, 791–794, 2004.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|