Size-resolved and bulk activation properties of aerosols in the North China plain: the importance of aerosol size distribution in the prediction of CCN number concentration

Author:

Deng Z. Z.,Zhao C. S.,Ma N.,Liu P. F.,Ran L.,Xu W. Y.,Chen J.,Liang Z.,Liang S.,Huang M. Y.,Ma X. C.,Zhang Q.,Quan J. N.,Yan P.,Henning S.,Mildenberger K.,Sommerhage E.,Schäfer M.,Stratmann F.,Wiedensohler A.

Abstract

Abstract. Size-resolved and bulk activation properties of aerosols were measured at a regional/suburban site in the North China Plain (NCP), which is occasionally heavily polluted by anthropogenic aerosol particles and gases. A CCN (Cloud Condensation Nuclei) closure study is conducted with bulk CCN number concentration (NCCN) and calculated NCCN based on the aerosol number size distribution and size-resolved activation properties. The observed NCCN are higher than those observed in other locations than China, with average NCCN of roughly 2000, 3000, 6000, 10 000 and 13 000 cm−3 at supersaturations of 0.056, 0.083, 0.17, 0.35 and 0.70%, respectively. An inferred critical dry diameter (Dm) is calculated based on the measured NCCN and aerosol number size distribution assuming homogeneous chemical composition. This inferred cut off diameter varies in a wide range, indicating that it is impossible to predict NCCN with a fixed critical diameter. Size-resolved activation measurements show that most of the 300 nm particles are activated at the investigated supersaturations, while almost no particles of 30 nm are activated even at the highest supersaturation of 0.72%. The activation ratio increases with increasing supersaturation and particle size. The slopes of the activation curves for ambient aerosols are not as steep as those observed in calibrations with ammonium sulfate suggesting that the observed aerosols is an external mixture of more hygroscopic and hydrophobic particles. This conclusion is confirmed by hygroscopicity measurements performed during two intensive field studies in 2009. The calculated NCCN based on the size-resolved activation ratio and aerosol number size distribution correlate well with the measured NCCN, and show an average overestimation of 19%. Sensitivity studies of the CCN closure show that the NCCN for each supersaturation is well predicted with the campaign average of size-resolved activation curves. These results indicate that the aerosol number size distribution is critical in the prediction of possible CCN. The NCCN can be estimated with average activation curve, along with a well described aerosol number size distribution.

Publisher

Copernicus GmbH

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3