Geoscientific process monitoring with positron emission tomography (GeoPET)
-
Published:2016-08-18
Issue:4
Volume:7
Page:1217-1231
-
ISSN:1869-9529
-
Container-title:Solid Earth
-
language:en
-
Short-container-title:Solid Earth
Author:
Kulenkampff JohannesORCID, Gründig Marion, Zakhnini Abdelhamid, Lippmann-Pipke Johanna
Abstract
Abstract. Transport processes in geomaterials can be observed with input–output experiments, which yield no direct information on the impact of heterogeneities, or they can be assessed by model simulations based on structural imaging using µ-CT. Positron emission tomography (PET) provides an alternative experimental observation method which directly and quantitatively yields the spatio-temporal distribution of tracer concentration. Process observation with PET benefits from its extremely high sensitivity together with a resolution that is acceptable in relation to standard drill core sizes. We strongly recommend applying high-resolution PET scanners in order to achieve a resolution on the order of 1 mm. We discuss the particularities of PET applications in geoscientific experiments (GeoPET), which essentially are due to high material density. Although PET is rather insensitive to matrix effects, mass attenuation and Compton scattering have to be corrected thoroughly in order to derive quantitative values. Examples of process monitoring of advection and diffusion processes with GeoPET illustrate the procedure and the experimental conditions, as well as the benefits and limits of the method.
Funder
Bundesministerium für Bildung und Forschung Bundesministerium für Wirtschaft und Energie Seventh Framework Programme
Publisher
Copernicus GmbH
Subject
Paleontology,Stratigraphy,Earth-Surface Processes,Geochemistry and Petrology,Geology,Geophysics,Soil Science
Reference62 articles.
1. Barth, T., Kulenkampff, J., Bras, S., Gründig, M., Lippmann-Pipke, J., and Hampel, U.: Positron emission tomography in pebble beds, Part 2: Graphite particle deposition and resuspension, Nucl. Eng. Des., 267, 227–237, 2014a. 2. Barth, T., Ludwig, M., Kulenkampff, J., Gründig, M., Franke, K., Lippmann-Pipke, J., and Hampel, U.: Positron emission tomography in pebble beds, Part 1: Liquid particle deposition, Nucl. Eng. Des., 267, 218–226, 2014b. 3. Basu, S., Zaidi, H., and Alavi, A.: Clinical and Research Applications of Quantitative PET Imaging, PET Clinics, 2, 161–172, 2007. 4. Bendriem, B. and Townsend, D. W.: The theory and practice of 3D PET, Developments in Nuclear Medicine, 32, edited by: Cox, P. H., Kluwer Academic Publishers, Dordrecht, 1998. 5. Benton, D. M. and Parker, D. J.: Non-medical applications of positron emission tomography, in: Non-Invasive Monitoring of Multiphase Flows, edited by: Chaouki, J., Larachi, F., and Dudukovic, M. P., Elsevier Science B.V., 161–184, 1996.
Cited by
18 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|