Design of an ozone and nitrogen dioxide sensor unit and its long-term operation within a sensor network in the city of Zurich
-
Published:2017-10-17
Issue:10
Volume:10
Page:3783-3799
-
ISSN:1867-8548
-
Container-title:Atmospheric Measurement Techniques
-
language:en
-
Short-container-title:Atmos. Meas. Tech.
Author:
Mueller Michael, Meyer Jonas, Hueglin ChristophORCID
Abstract
Abstract. This study focuses on the investigation and quantification of low-cost sensor performance in application fields such as the extension of traditional air quality monitoring networks or the replacement of diffusion tubes. For this, sensor units consisting of two boxes featuring NO2 and O3 low-cost sensors and wireless data transfer were engineered. The sensor units were initially operated at air quality monitoring sites for 3 months for performance analysis and initial calibration. Afterwards, they were relocated and operated within a sensor network consisting of six locations for more than 1 year. Our analyses show that the employed O3 and NO2 sensors can be accurate to 2–5 and 5–7 ppb, respectively, during the first 3 months of operation. This accuracy, however, could not be maintained during their operation within the sensor network related to changes in sensor behaviour. For most of the O3 sensors a decrease in sensitivity was encountered over time, clearly impacting the data quality. The NO2 low-cost sensors in our configuration exhibited better performance but did not reach the accuracy level of NO2 diffusion tubes (∼ 2 ppb for uncorrected 14-day average concentrations). Tests in the laboratory revealed that changes in relative humidity can impact the signal of the employed NO2 sensors similarly to changes in ambient NO2 concentration. All the employed low-cost sensors need to be individually calibrated. Best performance of NO2 sensors is achieved when the calibration models also include time-dependent parameters accounting for changes in sensor response over time. Accordingly, an effective procedure for continuous data control and correction is essential for obtaining meaningful data. It is demonstrated that linking the measurements from low-cost sensors to the high-quality measurements from routine air quality monitoring stations is an effective procedure for both tasks provided that time periods can be identified when pollutant concentrations can be accurately predicted at sensor locations.
Publisher
Copernicus GmbH
Subject
Atmospheric Science
Reference14 articles.
1. Alphasense Ltd.: available at: http://www.alphasense.com, last access: 28 April 2016. 2. Brunner, J. and Scheller, M.: Luftbilanz Stadt Zürich (Air quality report of the city of Zurich)., Tech. rep., no. 20140124, available at: https://www.stadt-zuerich.ch/content/dam/stzh/gud/Deutsch/UGZ/Gesundheitsschutz/Schadstoffe_Laerm_Strahlen/Aussenraum/Luft/%3E Dokumente und Publikationen/Luftbilanz/ugz_umw_la_20140124_luftbilanz_2012.pdf (last access: 12 September 2017), 2014 (in German). 3. Jiao, W., Hagler, G., Williams, R., Sharpe, R., Brown, R., Garver, D., Judge, R., Caudill, M., Rickard, J., Davis, M., Weinstock, L., Zimmer-Dauphinee, S., and Buckley, K.: Community Air Sensor Network (CAIRSENSE) project: evaluation of low-cost sensor performance in a suburban environment in the southeastern United States, Atmos. Meas. Tech., 9, 5281–5292, https://doi.org/10.5194/amt-9-5281-2016, 2016. 4. Li, J., Faltings, B., Saukh, O., Hasenfratz, D., and Beutel, J.: Sensing the Air We Breathe – The OpenSense Zurich Dataset, Proceedings of the Twenty-Sixth AAAI Conference on Artificial Intelligence, 2012. 5. Lin, C., Gillespie, J., Schuder, M., Duberstein, W., Beverland, I., and Heal, M.: Evaluation and calibration of Aeroqual series 500 portable gas sensors for accurate measurement of ambient ozone and nitrogen dioxide, Atmos. Environ., 100, 111–116, https://doi.org/10.1016/j.atmosenv.2014.11.002, 2015.
Cited by
71 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|