Technical note: Conservative storage of water vapour – practical in situ sampling of stable isotopes in tree stems
-
Published:2022-07-08
Issue:13
Volume:26
Page:3573-3587
-
ISSN:1607-7938
-
Container-title:Hydrology and Earth System Sciences
-
language:en
-
Short-container-title:Hydrol. Earth Syst. Sci.
Author:
Magh Ruth-KristinaORCID, Gralher Benjamin, Herbstritt BarbaraORCID, Kübert Angelika, Lim Hyungwoo, Lundmark Tomas, Marshall JohnORCID
Abstract
Abstract. Using water-stable isotopes to track plant water uptake or soil water processes has become an invaluable tool in ecohydrology and physiological ecology. Recent studies have shown that laser absorption spectroscopy can measure equilibrated water vapour well enough to support inference of liquid-stable isotope composition of plant or soil water, on-site and in real-time. However, current in situ systems require the presence of an instrument in the field. Here we tested, first in the lab and then in the field, a method for equilibrating, collecting, storing, and finally
analysing water vapour for its isotopic composition that does not require an instrument in the field. We developed a vapour storage vial system (VSVS) that relies on in situ sampling into crimp neck vials with a double-coated cap using a pump and a flow metre powered through a small battery and measuring the samples in a laboratory. All components are inexpensive and commercially available. We tested the system's ability to store the isotopic composition of its contents by sampling a range of water vapour of known isotopic compositions (from −95 ‰ to +1700 ‰ for δ2H) and measuring the isotopic composition after different storage periods. Samples for the field trial were taken in a boreal forest in northern Sweden. The isotopic composition was maintained to within 0.6 ‰ to 4.4 ‰ for δ2H and 0.6 ‰ to 0.8 ‰ for δ18O for natural-abundance samples. Although 2H-enriched samples showed greater uncertainty, they were sufficient to quantify label amounts. We detected a small change in the isotopic composition of the sample after a long storage period, but it was correctable by linear regression models. We observed the same trend for the samples obtained in the field trial for δ18O but observed higher variation in δ2H than in the lab trial. Our method combines the best of two worlds, sampling many trees in situ while measuring at high precision in the laboratory. This provides the ecohydrology community with a tool that is not only cost efficient but also easy to use.
Funder
Knut och Alice Wallenbergs Stiftelse
Publisher
Copernicus GmbH
Subject
General Earth and Planetary Sciences,General Engineering,General Environmental Science
Reference46 articles.
1. Allen, S. T. and Kirchner, J. W.: Potential effects of cryogenic extraction
biases on plant water source partitioning inferred from xylem-water isotope
ratios, Hydrol. Process., 36, e14483, https://doi.org/10.1002/hyp.14483, 2022. 2. Bates, D., Mächler, M., Bolker, B., and Walker, S.: Fitting Linear
Mixed-Effects Models Using lme4, J. Stat. Softw., 67, 1–48,
https://doi.org/10.18637/jss.v067.i01, 2015. 3. Beyer, M., Koeniger, P., Gaj, M., Hamutoko, J. T., Wanke, H., and Himmelsbach, T.: A deuterium-based labeling technique for the investigation
of rooting depths, water uptake dynamics and unsaturated zone water
transport in semiarid environments, J. Hydrol., 533, 627–643,
https://doi.org/10.1016/j.jhydrol.2015.12.037, 2016. 4. Beyer, M., Kühnhammer, K., and Dubbert, M.: In situ measurements of soil
and plant water isotopes: A review of approaches, practical considerations
and a vision for the future, Hydrol. Earth Syst. Sci., 24, 4413–4440,
https://doi.org/10.5194/hess-24-4413-2020, 2020. 5. Chen, Y., Helliker, B. R., Tang, X., Li, F., Zhou, Y., and Song, X.: Stem water cryogenic extraction biases estimation in deuterium isotope composition of plant source water, P. Natl. Acad. Sci. USA, 117, 33345–33350, https://doi.org/10.1073/pnas.2014422117, 2020.
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|