Author:
Dunlea E. J.,Herndon S. C.,Nelson D. D.,Volkamer R. M.,San Martini F.,Sheehy P. M.,Zahniser M. S.,Shorter J. H.,Wormhoudt J. C.,Lamb B. K.,Allwine E. J.,Gaffney J. S.,Marley N. A.,Grutter M.,Marquez C.,Blanco S.,Cardenas B.,Retama A.,Ramos Villegas C. R.,Kolb C. E.,Molina L. T.,Molina M. J.
Abstract
Abstract. Data from a recent field campaign in Mexico City are used to evaluate the performance of the EPA Federal Reference Method for monitoring ambient concentrations of NO2. Measurements of NO2 from standard chemiluminescence monitors equipped with molybdenum oxide converters are compared with those from Tunable Infrared Laser Differential Absorption Spectroscopy (TILDAS) and Differential Optical Absorption Spectroscopy (DOAS) instruments. A significant interference in the chemiluminescence measurement is shown to account for up to 50% of ambient NO2 concentration during afternoon hours. As expected, this interference correlates well with non-NOx reactive nitrogen species (NOz as well as with ambient O3 concentrations, indicating a photochemical source for the interfering species. A combination of ambient gas phase nitric acid and alkyl and multifunctional alkyl nitrates is deduced to be the primary cause of the interference. Observations at four locations at varying proximities to emission sources indicate that the percentage contribution of HNO3 to the interference decreases with time as the air parcel ages. Alkyl and multifunctional alkyl nitrate concentrations are calculated to be reach concentrations as high as several ppb inside the city, on par with the highest values previously observed in other urban locations. Averaged over the MCMA-2003 field campaign, the CL NOx monitor interference resulted in an average measured NO2 concentration up to 22% greater than that from co-located spectroscopic measurements. Thus, this interference has the potential to initiate regulatory action in areas that are close to non-attainment and may mislead atmospheric photochemical models used to assess control strategies for photochemical oxidants.
Reference69 articles.
1. Beauchamp, J., Wisthaler, A., Grabmer, W., Neuner, C., Weber, A., and Hansel, A.: Short-term measurements of CO, NO, NO2, organic compounds and PM$_10$ at a motorway location in an Austrian valley, Atmos. Env., 38, 2511–2522, 2004.
2. Blake, D. and Atlas, E.: Personal Communication, 2006.
3. Carslaw, D. C. and Beevers, S. D.: Investigating the potential importance of primary NO2 emissions in a street canyon, Atmos. Env., 38, 3585–3594, 2004.
4. Carslaw, D. C. and Beevers, S. D.: Estimations of road vehicel primary NO2 exhaust emission fractions using monitoring data in London, Atmos. Env., 39, 167–177, 2005.
5. Cavanagh, R. R. and Verkouteren, R. M.: Improving the Scientific Basis for Informed Decisions on Atmospheric Issues, NIST-NOAA-Industry Workshop on Atmospheric Measures and Standards, National Institute of Standards and Technology, 2001.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献